- YF 200A DC contactor
- YF 100A-2T DC contactor
- YF 100A-2 DC contactor
- YFT 100A DC contactor
- YFH 100A-2T DC contactor
- YFH 100A DC contactor
- YF 100A DC contactor
- YFT 50A DC contactor
- YF 100DE DC contactor for electric winch
- YF 50DE DC contactor for electric winch
- YF 50A DC contactor
- YFN DC contactor
- Power connector
- Emergency disconnect switch (Safety switch)
- YF3, YF3P DC contactor
- YF2, YF2P DC contactor
- YF1, YF1P DC contactor
- YF 500A DC contactor
- YFH 400A-2T DC contactor
- YFH 400A DC contactor
- YF 400A DC contactor
- YF5, YF5P DC contactor
- YF4, YF4P DC contactor
- YF6, YF6P DC contactor
- YFT200L, YFT200A DC contactor
- YFJ600A, YFJ600D DC contactor
- YFH 200A DC contactor
- YFH 200A-2T DC contactor
- YFD 200A series DC contactor
- YFD 400A series DC contactor
- YFD 600A series DC contactor
- YFJ 50A DC contactor
- YFJ100A, YFJ100D DC contactor
- YFJ200A, YFJ200D DC contactor
- YFJ400A, YFJ400D DC contactor
YFT 100A DC contactor
Application:
YFT100A series DC contactors are suitable for the battery or the rectificationpower, using for handling drawing, the pump motor and other electronicvehicles. At the same time it has been widely used in communications power, UPS(uninterruptible power system) and other electronic control system.
Brief Technical Data:
| Number | Type and parameter | Coil and rated volt of contact circuit(v) | ||||||||
| 12 | 24 | 3 0 | 36 | 40 | 48 | 60 | 72 | 8 80 | ||
| 1 | Coil power dissipation <15(w), Max.coil current(A) | 0.98 | 0.58 | 0.45 | 0.35 | 0.32 | 0.28 | 0.25 | 0.2 | 0.18 |
| 2 | main rated load current of contact circuit(A) | Resistive load:=1ms 100A | ||||||||
| 3 | voltage | 50Hz 1000V AC 1min | ||||||||
| 4 | Operating time | Pickup(contact makes):30ms , Release(contact breaks):30ms | ||||||||
| 5 | Action characteristic | Pickup(contact makes):66%Us | ||||||||
| 6 | Mechanical life | 1 million times | ||||||||
| 7 | Electric life | Resistive load:20000times, inductive load(DC-5):60%le for Resistive load,10000times | ||||||||
| Notice: | ||||||||||
Environmentalcondition:
1. Ambient temperature:-25~+40
2. Altitude range:0~2000m
3. Max.relative humidity90% at 25
4. Vibration:10~50Hz,10m/s2
5. Shock:30m/s2
6. Installation method:anywhere
7. Voltage fluctuating:0.7~1.1Ue
8. Duty:8h continuous
Configurational mounting diagram:
Circuit diagram:
Nomination(nomogram):

- YF 100A-2 DC contactor YF100A-2 DC contactorApplication:YF100A-2 series DC contactors are suitable for the battery or the rectificationpower, using for handling drawing, the

- YF 100A-2T DC contactorYF100A-2T DC contactorApplication:YF100A-2T series DC contactors are suitable for the battery or therectification power, using for handling drawing, t

- YF 200A DC contactor YF 200A DC contactorApplication:YF200A series DC contactors are suitable for the battery or the rectificationpower, using for handling drawing, the pu

- YFJ400A, YFJ400D DC contactor YFJ400A, YFJ400D DC contactorApplication:YFJ400A , YFJ400D contactor is applicable for electric control system of electromobile, motor forklift truck,

- YFJ200A, YFJ200D DC contactor YFJ200A, YFJ200D DC contactorApplication:YFJ200A , YFJ200D contactor is applicable for electric control system of electromobile, motor forklift truck,


United Kingdom


English
Русский