- YF 200A DC contactor
- YF 100A-2T DC contactor
- YF 100A-2 DC contactor
- YFT 100A DC contactor
- YFH 100A-2T DC contactor
- YFH 100A DC contactor
- YF 100A DC contactor
- YFT 50A DC contactor
- YF 100DE DC contactor for electric winch
- YF 50DE DC contactor for electric winch
- YF 50A DC contactor
- YFN DC contactor
- Power connector
- Emergency disconnect switch (Safety switch)
- YF3, YF3P DC contactor
- YF2, YF2P DC contactor
- YF1, YF1P DC contactor
- YF 500A DC contactor
- YFH 400A-2T DC contactor
- YFH 400A DC contactor
- YF 400A DC contactor
- YF5, YF5P DC contactor
- YF4, YF4P DC contactor
- YF6, YF6P DC contactor
- YFT200L, YFT200A DC contactor
- YFJ600A, YFJ600D DC contactor
- YFH 200A DC contactor
- YFH 200A-2T DC contactor
- YFD 200A series DC contactor
- YFD 400A series DC contactor
- YFD 600A series DC contactor
- YFJ 50A DC contactor
- YFJ100A, YFJ100D DC contactor
- YFJ200A, YFJ200D DC contactor
- YFJ400A, YFJ400D DC contactor
YFN DC contactor
Usage:
YFN 100A, 200Aseries contactors are suitable for electric control system of electromobile, motor forklift truck, especially for themaintenance of vehicles.
Brief Technical Data:
| Number | Type and parameter | Coil& rated volt of contact circuit(v) | |||||||
| 12 | 24 | 30 | 36 | 40 | 48 | 72 | 80 | ||
| 1 | YFN100A coil hold current(A) | 0.83 | 1.65 | ||||||
| 2 | YFN200A coil hold current(A) | 0.73 | 1.45 | ||||||
| 3 | YFN100A main rated load current of contact circuit(A) | Resistive load=1ms,100A,Inductive load(DC-5)60%lefor resistive load | |||||||
| 4 | YFN200A main rated load current of contact circuit(A) | Resistive load=1ms,200A, Inductive load(DC-5)60%le for resistive load | |||||||
| 5 | voltage | 50Hz 1000V AC 1min | |||||||
| 6 | Operating time | pickup(contact makes)30ms:release(contact breaks)30ms | |||||||
| 7 | Action characteristic | pickup(contact makes)66%Us | |||||||
| 8 | Mechanical life | 1 million times | |||||||
| 9 | Electric life | Resistive load:50000times Inductive load 60%le for resistive load 20000times | |||||||
Specifications subject to change as thecustom request
Environmental condition:
1. Ambient temperature:-25~+40
2. Altitude range:0~2000m
3. Max.relative humidity90% at 25
4. Vibration:10~50Hz,10m/s2
5. Shock:30m/s2
6. Installation method:anywhere
7. Voltage fluctuating:0.7~1.1Ue
8. Duty:8h continuous
Configurational mounting diagram:
Circuit diagram:
Nomination(nomogram):

- YF 50A DC contactor YF 50A DC contactorApplication:YF 50A series DC contactors are suitable for the battery or the rectificationpower, using for handling drawing, the pum

- YF 50DE DC contactor for electric winch YF 50DE DC contactor for electric winch Application:YF50DE DC contactor for electric winch is used in electric winch supportingmotorcar, with high and

- YF 100DE DC contactor for electric winchYF 100DE DC contactor for electric winchApplication: YF100DE DC contactor for electric winch is used in electric winch supportingmotorcar, with high a

- YFT 50A DC contactorYFT 50A DC contactorApplication:YFT50A series DC contactors are suitable for the battery or the rectificationpower, using for handling drawing, the pu

- YF 100A DC contactor ZJW100A DC contactor YF 100A DC contactorApplication:YF100A series DC contactors are suitable for the battery or the rectificationpower, using