- YF 200A DC contactor
- YF 100A-2T DC contactor
- YF 100A-2 DC contactor
- YFT 100A DC contactor
- YFH 100A-2T DC contactor
- YFH 100A DC contactor
- YF 100A DC contactor
- YFT 50A DC contactor
- YF 100DE DC contactor for electric winch
- YF 50DE DC contactor for electric winch
- YF 50A DC contactor
- YFN DC contactor
- Power connector
- Emergency disconnect switch (Safety switch)
- YF3, YF3P DC contactor
- YF2, YF2P DC contactor
- YF1, YF1P DC contactor
- YF 500A DC contactor
- YFH 400A-2T DC contactor
- YFH 400A DC contactor
- YF 400A DC contactor
- YF5, YF5P DC contactor
- YF4, YF4P DC contactor
- YF6, YF6P DC contactor
- YFT200L, YFT200A DC contactor
- YFJ600A, YFJ600D DC contactor
- YFH 200A DC contactor
- YFH 200A-2T DC contactor
- YFD 200A series DC contactor
- YFD 400A series DC contactor
- YFD 600A series DC contactor
- YFJ 50A DC contactor
- YFJ100A, YFJ100D DC contactor
- YFJ200A, YFJ200D DC contactor
- YFJ400A, YFJ400D DC contactor
YF 50A DC contactor
Application:
YF 50A series DC contactors are suitable for the battery or the rectificationpower, using for handling drawing, the pump motor and other electronicvehicles. At the same time it has been widely used in communications power,intermittent power supply and other electronic control system
Brief Technical Data:
| Number | Type and parameter | Coil& rated volt of contact circuit(v) | ||||||||
| 12 | 24 | 3 0 | 36 | 40 | 48 | 60 | 72 | 8 80 | ||
| 1 | Coil power dissipation <15(w), Max.coil current(A) | 0.98 | 0.58 | 0.45 | 0.35 | 0.32 | 0.28 | 0.25 | 0.2 | 0.18 |
| 2 | main rated load current of contact circuit(A) | Resistive load:=1ms 50A | ||||||||
| 3 | voltage | 50Hz 1000V AC 1min | ||||||||
| 4 | Operating time | Pickup(contact makes):30ms , Release(contact breaks):30ms | ||||||||
| 5 | Action characteristic | Pickup(contact makes):66%Us | ||||||||
| 6 | Mechanical life | 1 million times | ||||||||
| 7 | Electric life | Resistive load:50000times,inductive load(DC-5): 60%le for Resistive load,10000times | ||||||||
| Notice: | ||||||||||
Environmentalcondition:
1. Ambient temperature:-25~+40
2. Altitude range:0~2000m
3. Max.relative humidity 90% at 25
4. Vibration:10~50Hz,10m/s2
5. Shock:30m/s2
6. Installation method:anywhere
7. Voltage fluctuating:0.7~1.1Ue
8. Duty:8h continuous
Configurational mounting diagram:
Circuit diagram:
Nomination(nomogram)

- YF 50DE DC contactor for electric winch YF 50DE DC contactor for electric winch Application:YF50DE DC contactor for electric winch is used in electric winch supportingmotorcar, with high and

- YF 100DE DC contactor for electric winchYF 100DE DC contactor for electric winchApplication: YF100DE DC contactor for electric winch is used in electric winch supportingmotorcar, with high a

- YFT 50A DC contactorYFT 50A DC contactorApplication:YFT50A series DC contactors are suitable for the battery or the rectificationpower, using for handling drawing, the pu

- YF 100A DC contactor ZJW100A DC contactor YF 100A DC contactorApplication:YF100A series DC contactors are suitable for the battery or the rectificationpower, using

- YFH 100A DC contactor YFH 100A DC contactorApplication: YFH100A series DC contactors are suitable for the battery or the rectificationpower, using for handling drawing, the


United Kingdom


English
Русский