- Condenser Series
- Air-coolers
- Liquid Line Block
- Temperature Controller
- R-1 External Rotor Fan
- V-1 Sight Glass
- Solenoid Valves
- W-2 Oil Separators
- W-1 Oil Separators
- Refrigeration Components
- Liquid Receiver Series
- Q Series Double Side Blowing Air Coolers
- K Series Water Defrosting Air Coolers
- G Series Air Coolers
- F Series Air Cooler
- Heat Exchanger Products
- TU Series Box Type Condensing Units
- BT Series Box Type Condensing Units
- BC Series Box Type Condensing Units
- MC Series Integrated Machine for Cold Storage
- Condensing Units
- Related Refrigeration Equipment
- Heat Insulation Panel
- X Series Air Cooled Condensers
- I Series Air Coolers
- R Series Screw Compressor Condensing Units
- PM Series Multi-paralleled Condensing Units
- T series Two-stage Compressor Condensing Units
- SD Series Condensing Units
- Refrigerant
- Z Series Shell and Pipe Evaporators
- Y Series Water Cooled Condensers
- CA Series Air-cooled Condensing Units
- CW Water -cooled Condensing Units
- LC Series Low Noise Condensing Units
- Industrial Chillers
- Single Stage Rotary Vacuum Pumps
V-1 Sight Glass
The sight glass is the important refrigerationequipment. The indicator provided by this sight glass can tell the watercontent in the refrigeration agent by variation of colors. It looks mazarine blue when the refrigeration agent has the leastmoisture content, while it looks pink for maximum moisture content. At thattime, it means that the dry filter needs replacement. Medium temperature isbetween -50 and + 80. Applicable media: CFC, HCFC, HFC, andHCFV.
The sight glass canbe used to indicate the following:
1) Refrigerant state in liquid line in the refrigerating plant.
2) Liquid water content of refrigerant.
3) Liquid flow in oil return pipe from oil separator to compressor.
Technicalspecifications
For welding connection
| Model | Coupling | Outside diameter of connection tube | |
| British system | Metric system | ||
| V-16 | Welding flaring | 6 | |
| V-14 | 1/4 | ||
| V-10 | 10 | ||
| V-13 | 3/8 | ||
| V-12 | 12 | ||
| V-11 | 1/2 | ||
| V-18 | 16 | ||
| V-15 | 5/8 | ||
| V-19 | 19 | ||
| V-34 | 3/4 | ||
| V-22 | 22 | ||
| V-78 | 7/8 | ||
| V-28 | 28 | ||
| V-108 | 1-1/8 | ||
For screw thread connection
| Model | Coupling | Outside diameter of connection tube | |
| British system | Metric system | ||
| V-101 | Bell mouthing screw thread | 6 | |
| V-102 | 10 | ||
| V-103 | 12 | ||
| V-104 | 16 | ||
| V-105 | External thread-internal thread | 6 | |
| V-106 | 10 | ||
| V-107 | 12 | ||
| V-108 | External thread-nut | 10 | |
| V-109 | 12 | ||
| V-110 | Nut-nut | 10 | |
| V-111 | 12 | ||
| V-112 | Directly welded to the system pipeline | 1" | |
| V-113 | 1-1/2" | ||
| V-114 | 2" | ||