- Inverter
- Gallery
- Principle,Wiring
- Technical Parameters
- Gallery
- Physical Features
- Physical Features
- Technical Parameters
- Principle,Wiring
- Applications
- CATV UPS, EX-0614
- DC Axial UPS Cooling Fan
- UPS Cooling Fan
- 10-20kVA UPS
- 20kVA UPS and UPS higher than 20kVA
- 6-10kVA UPS
- 1-3kVA UPS
- 500VA-1200VA UPS
- HW9110E High Performance Integrated Outdoor Online UPS, 1kVA-10kVA
- GM Series 6 - 20kVA
- G Series 1 - 3kVA
- GM Series 6 - 20kVA
- G Series 1 - 3kVA
- LG Series 500-1200VA
- ST Series 1 - 3kVA
- HP9330C Series 10 - 80kVA
- GP Series 10 - 200kVA
- GP Series 6 - 30kVA
- HP9116C & HP9316C Series 6-20kVA UPS
- HP9116C Series 1 - 3kVA
- B Series 500-1200VA
- ST Series 1 - 3kVA
- HP9117C series1 - 3kVA
- GP series 10-200kVA UPS
- GP series 6-30kVA UPS
- HP9330C Series 10 - 80kVA
- HP9116CR & HP9316CR series 1-10kVA UPS
- HP9116C & HP9316C Series 6-20kVA UPS
- HP9116C Series 1 - 3kVA
- G / GM Series 6 - 20kVA
- G / GM Series 1 - 3kVA
- ST Series 1 - 3kVA
- GP series 10-200kVA UPS
- GP series 6-30kVA UPS
- HP9330C series 20-80kVA UPS
- HP9116CR & HP9316CR series 1-10kVA UPS
- HP9116C & HP9316C series 6-20kVA UPS
- HP9116C Series 1-3kVA UPS
- G-GM series 6-20kVA UPS
- G-GM Series 1-3kVA UPS
- Difference Between EPS and UPS
- Passive Power Filter
- Active Power Filter (APF)
- Power Filter
- UPS Cooling Fan
- UPS Battery Charger
- UPS SNMP Card
- Inverter UPS Accessories
- Lighting Power EPS (Emergency Power Supply)
- Lighting EPS (Emergency Power Supply)
- EPS (Emergency Power Supply)
- UPS System
- LED UPS
- LCD UPS
- Low Frequency Online UPS
- High Frequency Online UPS
- ST Series 1-3kVA UPS
- HP9117C Series 1-3kVA UPS
- Online UPS
- UPS (Uninterruptible Power Supply)
- Off Line UPS
UPS Battery Charger
Features of UPS Battery Charger
1. Our UPS battery charger employs modularization design, and realizes N+1 backup.
2. Man-machine interface and large LED digital screen design.
3. RS-485 interface board is compatible with our UPS battery charger.
4. Remote monitoring function.
5. Its working efficiency is quite high, and can reaches nearly 95%-96%.
6. It is small in volume and light in weight. The dimension of 230/10A natural cooling module is just 325230130 mm, and the weight is only 9kg.
7. AC-DC transformation
The full bridge will firstly rectify circuit from 3-phase AC to DC, and then reactive PFC adjusts the circuit again.
8. The power factor of our UPS battery charger is above 0.94.
9. Diodes are installed in each module to against reverse pour at output terminal.
10. Digital calibration, stable current, and fault alarm.
Protection Functions of UPS Battery Charger
1. Output overvoltage protection
Overvoltage protection circuit is designed in the module. Once output overvoltage occurs, the module will lock up and stop working automatically. Meanwhile, the relative module fault indication light goes on. This process won\'t affect the normal operation of the entire system.
The overvoltage protection point is set during the production. 320V5% is set for rated output 220V machine type, and 160V5% is set for rated output 110V machine type.
2. Output current limiting protection
The maximum value of the output current of each module is limited to the rated output current 105%. Within this range, you can adjust the valve in accordance with your needs.
If the output current value exceeds the load capacity of the module, the module will play down the output voltage.
3. Output short-circuit protection
When output short circuit occurs, the module will automatically decrease the output voltage to zero, and only permit 15% current to pass through it.
The module will not be damaged under short circuit, and can go back to work automatically after debugged.
4. Module parallel protection
Parallel protection circuit is designed to ensure the normal operation of other modules and systems while one of the modules goes wrong.
5. Over-temperature protection
6. Output over-current protection
SH Power Co.,Ltd. is an enterprise greatly supported by the national science and technology department. Its TH series high-frequency switch power supply module can satisfy all requirements of modern electric system, and extensively applicable to many fields, such as computer, aviation, instrument, and telecommunications.
Apart from UPS battery chargers, we also provide LCD UPS, LED UPS, lighting EPS, and more. All our products are CE certified and widely exported to many parts of the world such as Europe, America, Africa, Southeast Asia, etc.
For further information of UPS battery charger or any of our UPS products, please do contact us. We are competent and are your one stop shopping centre for all your UPS needs.
Thank you very much for visiting our site!

- UPS Cooling Fan UPS Cooling Fan-->AC / DC Cooling Fans and BlowersNMB\'s cooling fans and blowers can provide a good cooling solution for the thermal problems ca

- Power Filter Power FilterOur power filters can be classified as active power filters and passive power filters. The active power filter (APF) is new-style power e

- Active Power Filter (APF) Active Power Filter (APF)Our active power filter is an advanced power electronic device. It is designed with a digital signal processor, and employs

- Passive Power Filter Passive Power FilterOur SPF series passive power filter is designed for different loading solutions. It can filter harmonic and provide capacitive re

- Difference Between EPS and UPS Difference Between EPS and UPSItemEPS(three phases emergency power supply)UPS (uninterruptible power supply)Electricity savingIt operates in sleep mo


United Kingdom


English
Español
Русский