Product List
- Quick Link
- 资料提供须知
- R & D Team
- R & D
- News
- Tube Filling and Sealing Machine (GF-400 Series)
- Wall Mounted Speaker HSD311(W/B), HSD312(W/B), HSD313(W/B)
- Ceiling Speaker HSD703
- Stereo Amplifier MX1000, MX1500, MX2000, MX2500
- Power Amplifier MP6425, MP6438, MP6450
- Dual Channel Power Amplifier MAG1306II, MAG1312II, MAG1325II, MAG1335II
- Power Amplifier MP1510, MP2010, MP2510; MP3010, MP3510, MP4010
- Power Amplifier PC1700, PC2200, PC2700; PC3200, PC3700, PC4200
- Power Amplifier MP1600, MP2100, MP2600; MP3100, MP3600, MP4100
- Power Amplifier MP1500, MP2000, MP2500; MP3000, MP3500, MP4000
- Mixing Amplifier MP210P, MP310P, MP610P, MP1010P
- Classroom Amplifier MP220PII
- Vacuum Forming Machine (ZPQ-250)
- Food Blister Packing Machine DPB-250 Series (Chocolate, Jam, Butter, Candy)
- Capsule Orientation Device (JD Series)
- Automatic Strip Packing Machine (DLL-160C)
- Servo Blister Packing Machine (DPB-140C)
- All-in-One Amplifier MP9006, MP9012, MP9025, MP9035
- Network Public Address Centre MAG5182,Network PA System
- Remote Paging Microphone MAG5488,Network PA System
- Programmable Player MAG5366,Network PA System
- Audio-on-Demand Terminal MAG5402,Network PA System
- Network Player MAG5401,Network PA System
- Optional Modules: Alarm Input Module MAG1880;Alarm Output Module MAG1832;Telephone Module MAG1824;Remote Paging Module MAG1826;Periphery Control Modul
- Standard Modules: Priority Input Module MAG1821; Normal Input Module MAG1822; Output Module MAG1864; Monitor Module MAG1818,Intelligent PA System
- M/S Pre-Amplifier Selector MAG1548,Intelligent PA System
- Remote Paging Microphone MAG1488II,Intelligent PA System
ManufacturersSStandard Modules: Priority Input Module MAG1821; Normal Input Module MAG1822; Output Module MAG1864; Monitor Module MAG1818,Intelligent PA SystemStandard Modules: Priority Input Module MAG1821; Normal Input Module MAG1822; Output Module MAG1864; Monitor Module MAG1818,Intelligent PA System
Standard Modules: Priority Input Module MAG1821; Normal Input Module MAG1822; Output Module MAG1864; Monitor Module MAG1818,Intelligent PA System
Standard Modules: Priority Input Module MAG1821; Normal Input Module MAG1822; Output Module MAG1864; Monitor Module MAG1818,Intelligent PA System
The back of every
Intelligent PA Host has 12 lines of function slots for 12 function modules at
most. For more modules, it must add MAG 1200 series intelligent extender, which
may add 12 pieces function modules more. The master and extender or two
extenders can be connected by 2 cables form the interface "link1" and "link2".
Standard Modules: Priority Input Module MAG1821; Normal Input Module MAG1822; Output Module MAG1864; Monitor Module MAG1818,Intelligent PA System
Standard Modules :
Priority Input Module MAG1821
Normal Input Module MAG1822
Output Module MAG1864
Monitor Module MAG1818
Functional Modules
According to the needs of different occasions, MAG PA centre could let user choose appropriate modules for system running. To ensure the system's performance, installing module should only be left to authorized dealers. The table below shows the use of optional function modules and the quantity of them.
|
No.
|
Module
|
Functions
|
Quantity
|
|
1
|
Prior Input Module
MAG1821
|
Essential Module, 4 audio inputs ( MIC. or Line level) with priority order
merge into one, signal can be located to any output channel, and Fire function
is available
|
1 pc
|
|
2
|
Normal Input Module
MAG1822
|
4 audio inputs (MIC. or Line level) each input processed individually,
signals can be located to any output channel
|
0-2 pcs
|
|
3
|
Output Module
MAG1864
|
Essential module, 4 audio outputs, each one can apply any input
signal
|
1-16 pcs
|
|
4
|
EMC Input Module
MAG1880
|
Each module can receive 16 channels of emergency signals from emergency
centre, programmable, compatible with High/Low level respond
|
0-4 pcs
|
|
5
|
EMC Output Module
MAG1832
|
Outputs of 16 channels of fire functional signals for activating of alarms,
paging and phone-calls
|
0-4 pcs
|
|
6
|
Monitor Module
MAG1818
|
Essential Module, for auto/manual monitoring all and any sound
channels
|
1 pc
|
|
7
|
Phone Module
MAG1824
|
Telephone interface with password protection, can pick up or hang up calls
automatically, receiving zones can be set or pre set
|
0-1 pcs
|
|
8
|
Remote Paging Module
MAG1826
|
Remote paging interface, enable external remote for any zone paging , range
can be up to 1 km
|
0-4 pcs
|
|
9
|
Periphery Control Module
MAG1820
|
Enable monitoring and operating on intelligent amplifiers and other DSP
products
|
0-4 pcs
|
|
10
|
Amplifier Communication Module MAG1300
|
Fixed into MAG dual channel amplifier, allow MAG control center to check
the status of amplifier
|
1 pc each amplifier
|
Feedback Form
Other Products

- Optional Modules: Alarm Input Module MAG1880;Alarm Output Module MAG1832;Telephone Module MAG1824;Remote Paging Module MAG1826;Periphery Control ModulOptional Modules: Alarm Input Module MAG1880;Alarm Output Module MAG1832;Telephone Module MAG1824;Remote Paging Module MAG1826;Periphery Control Modul

- Network Player MAG5401,Network PA SystemNetwork Player MAG5401,Network PA SystemNetwork Player MAG5401,Network PA System FEATURES: It can be connected to the LAN anywhere; Broadcast p

- Audio-on-Demand Terminal MAG5402,Network PA SystemAudio-on-Demand Terminal MAG5402,Network PA SystemAudio-on-Demand Terminal MAG5402,Network PA System FEATURES: The network system programs on dema

- Programmable Player MAG5366,Network PA SystemProgrammable Player MAG5366,Network PA SystemProgrammable Player MAG5366,Network PA System FEATURES: It can be connected to the LAN anywhere; A

- Remote Paging Microphone MAG5488,Network PA SystemRemote Paging Microphone MAG5488,Network PA SystemRemote Paging Microphone MAG5488,Network PA System FEATURES: To control up to 200 zones. The


United Kingdom

English
Français
Español