Featuring their Semi-Hermetic Bitzer compressor, the condensing units include 4 series ofproducts of air cooled and water cooled, middle and high, middle and lowtemperature range.

Technicalspecification
(Air cooled middleand high temperature units)

Model

Input

Capacity

Pipe

Over all (mm)

Inst size(mm)

KW

W

Gas

Liquid

A

B

C

a

b

SD-1

1.94

3380

16

10

620

650

560

580

350

SD-2

2.23

3990

16

10

620

650

560

580

350

SD-3

2.7

4820

16

10

620

650

560

580

350

SD-4

3.34

5670

22

12

960

680

460

920

380

SD-5

3.88

6780

22

12

960

680

510

920

380

SD-6

4.92

8350

22

12

1060

680

720

1020

380

SD-7

5.21

9640

22

12

1300

750

670

1260

410

SD-8

6.23

11850

28

12

1300

750

770

1260

410

SD-9

7.72

14480

28

16

1300

750

870

1260

410

SD-10

7.98

17500

28

16

1280

710

1010

1000

665

SD-11

7.91

19190

28

16

1280

710

1010

1000

665

SD-12

9.85

23150

35

16

1280

710

1210

1000

665

SD-13

11.2

27700

35

22

1280

750

1460

1000

705

SD-14

14.1

32150

42

22

1350

800

1410

1000

755

SD-15

18.1

42250

54

22

1150

570

860

800

525

SD-16

21.1

48500

54

22

1150

570

852

800

525

SD-17

26.7

63400

54

28

1050

600

910

800

555

SD-18

31

72800

54

28

1050

600

910

800

555

SD-19

37.9

86300

54

35

1600

610

880

1000

550

Remarks:
1. Test condition:-5/ 50.
2. Power supply: 380V/50HZ.
3. Refrigerant for all is R22.

Air cooled middleand low temperature units:

Model

Input

Capacity

Pipe

Over all (mm)

Inst size(mm)

KW

W

Gas

Liquid

A

B

C

a

b

SD-20

1.37

1880

16

10

620

650

510

580

350

SD-21

1.85

2700

16

10

620

650

510

580

350

SD-22

2.22

3150

22

10

620

650

560

580

350

SD-23

2.64

3520

22

12

960

680

470

920

380

SD-24

3.03

4450

22

12

960

680

520

920

380

SD-25

3.6

4960

22

12

1060

680

620

1020

380

SD-26

4.37

6160

22

12

1300

750

670

1260

410

SD-27

5.0

7280

28

12

1300

750

770

1260

410

SD-28

6.2

8390

28

12

1300

750

870

1260

410

SD-29

7.38

11880

35

16

1280

710

1010

1000

665

SD-30

8.67

13800

35

16

1280

710

1210

1000

665

SD-31

10

16150

35

16

1280

750

1460

1000

705

SD-32

13.9

21100

42

22

1350

850

1410

1000

805

SD-33

16.4

24450

54

22

1350

850

1410

1000

805

SD-34

20.7

31700

54

22

1150

570

850

800

525

SD-35

24.3

36700

54

22

1150

570

850

800

525

SD-36

29.6

44100

54

28

1050

600

910

800

555

Remarks:
1. Test condition:-5/ 50.
2. Power supply: 380V/50HZ.
3. Refrigerant for all is R22.
4. The CIC liquid injection system is needed at the lower temperature.

Water cooledmiddle and high temperature units

Model

Input

Capacity

water

Pipes

Over all (mm)

Install(mm)

KW

W

m3/h

Gas

Liquid

water

A

B

C

a

b

SD001

2.0

5590

1.7

16

12

11/4

750

365

530

510

290

SD002

2.4

6660

2.0

22

12

11/4

840

365

560

510

290

SD002

2.7

7980

2.4

22

12

11/4

840

365

560

510

290

SD004

3.3

9890

2.9

22

16

11/2

940

400

620

600

320

SD005

3.7

11230

3.3

22

16

11/2

1090

400

670

710

320

SD006

4.6

13860

4.0

28

16

11/2

1090

400

670

710

320

SD007

5.4

16830

4.9

28

22

2

1260

410

670

800

320

SD008

6.6

20250

5.9

28

22

2

1260

410

670

800

320

SD009

6.6

22250

6.4

28

22

2

1300

470

770

850

390

SD010

8.1

26800

7.7

35

22

2

1300

470

770

850

390

SD012

9.4

31950

9.0

35

28

2

1300

470

770

850

390

SD013

11.3

37000

10.6

42

28

2

1300

563

770

850

390

SD014

14.2

47400

13.5

54

28

2

1300

563

840

850

390

SD015

16.8

54400

15.7

54

28

2

1300

563

840

850

390

SD016

21.3

71200

20.4

54

35

21/2

1060

620

850

1000

550

SD017

25.2

81600

23.5

54

35

21/2

1060

620

850

1000

550

SD018

31.4

96500

28

54

35

21/2

2100

620

850

1200

550

Remarks:
1. Test condition:-5/ 50.
2. Power supply: 380V/50HZ.
3. Refrigerant for all is R22.

Water cooledmiddle and low temperature units

Model

Input

Capacity

water

Pipes

Over all (mm)

Install(mm)

KW

W

m3/h

Gas

Liquid

water

A

B

C

a

b

SD020

2.6

5400

1.8

22

12

11/4

840

365

560

510

290

SD021

3.0

6010

2

22

16

11/2

940

400

670

600

320

SD022

3.7

7550

2.5

22

16

11/2

940

400

670

600

320

SD023

4.4

8830

3

28

16

11/2

1090

400

670

710

320

SD024

5.2

10230

3.5

28

16

11/2

1090

400

670

710

320

SD025

6.4

14150

4.5

35

22

2

1260

410

720

800

320

SD026

7.4

16390

5.3

35

22

2

1260

410

720

800

320

SD027

8.7

19160

6

35

22

2

1300

470

770

850

390

SD028

11.2

24450

8

42

28

2

1300

563

840

850

390

SD029

13.1

28200

9

54

28

2

1300

563

840

850

390

SD030

16.8

36700

12

54

28

2

1300

595

830

850

390

SD031

19.6

42300

14

54

28

21/2

1660

600

850

1000

550

SD032

24.3

50500

16.5

54

35

21/2

1660

620

850

1000

550

Remarks:
1. Test condition:-5/ 50.
2. Power supply: 380V/50HZ.
3. Refrigerant for all is R22.
4. The CIC liquid injection system is needed at the lower temperature.

Feedback Form
Other Products
  • I Series Air Coolers I Series Air CoolersThe air coolers, the high quality refrigerationequipment manufactured by our company, can be divided into different groups bytempe
  • X Series Air Cooled CondensersX Series Air Cooled CondensersThe air cooled condensers are air cooledheat exchangers for refrigeration system. They have been tested on 2.8MPa airlea

United States | Argentina | Brazil | China | France | Germany | Japan | Korea | Russia | Spain | Switzerland | Thailand | UAE | United Kingdom | Vietnam | Poland | Italy | Morocco | Malaysia | Portugal | India | Canada

Copyright © 2008 - ETW International. All rights reserved.