- Panel Meter
- Digital Multimeter
- PT-2 Three Phase Electromechanical Watt-Hour Meter
- PT-1 Three Phase Electromechanical Watt-Hour Meter
- PS-8 Single Phase Prepaid Electronic Meter - KWH Meter
- PS-7 Single Phase Multi-function Watt-Hour Meter
- PS-6 Single Phase Static Watt-Hour Meter
- PS-5 Single Phase Electromechanical Watt-Hour Meter
- PS-3 Single Phase Electromechanical Watt-Hour Meter
- PS-2 Single Phase Watt-Hour Meter
- Panel Meter
- Digital Multimeter
- PSA-5 Single Phase Electronic KWH Meter
- PSA-3 Single Phase Electronic KWH Meter
- PTA-2 Three Phase Electronic Multi-rate Watt-Hour Meter
- PSA-9 Single Phase Electronic Multi-rate Watt-Hour Meter
- PTA-1 Three Phase Electronic Watt-Hour Meter
- PSA-2 Single Phase DIN-rail Watt-Hour Meter
- PSA-1 Single Phase Electronic Watt-Hour Meter
- PT-6 Three Phase Electronic Prepaid Watt-Hour Meter
- PT-5 Three Phase Static Multi-function Energy Meter
- PT-3 Three Phase Static Active Watt-Hour Meter
- PT-2 Three Phase Electromechanical Watt-Hour Meter
- PT-1 Three Phase Electromechanical Watt-Hour Meter
- PS-8 Single Phase Prepaid Electronic Meter - KWH Meter
- PS-7 Single Phase Multi-function Watt-Hour Meter
- PS-6 Single Phase Static Watt-Hour Meter
- PS-5 Single Phase Electromechanical Watt-Hour Meter
- PS-3 Single Phase Electromechanical Watt-Hour Meter
- PS-2 Single Phase Watt-Hour Meter
- PS-1 Single Phase Watt-Hour Meter (Kilowatt Hour Meter)
- RA-2 Reactive Auto-compensation Power Controller
- RA-1 Reactive Auto-compensation Power Controller
- Low Voltage Power Capacitor
- TF Full Film Type H.V. Power Capacitor
- SH Self Healing Low Voltage Capacitor
- Power Capacitor / Power Controller
- Single Phase Watt-Hour Meter / KWH Meter (Kilowatt Hour Meter)
RA-2 Reactive Auto-compensation Power Controller
RA-2 Reactive Auto-compensation Power Controller
Description
RA-2 series reactive auto compensating power controller is suitable forself-adjusting capacitor compensation devices in low voltage distributionincrease the efficiency of the power transformer, reduce line loss, and improvevoltage quality. On final aim it will increase the economic and socialbenefits.
Technical Data
Basic Parameter
Rated voltage: AC 380/AC 22010%
Rated current: AC 0-5A
Rated frequency: 50Hz5%
Control Parameters
Sensitivity: 100mA
Targe COS Preset:0.70-0.99; step length 0.01; Factory preset 0.98 input and cutoff time delay:dynamic state 100ms-30S; Static state 1-250S;
Over-voltage protection: 380-500V/230-260V; step length 1V; Return difference6V
Under-voltage protection: 340V/180V; Return difference 6V
CT variation: 50/5A-3000/5A: step length 1; Factory preset 500/5A
Capacitance capacity: dynamic state output of each branch DC12V50mA
static state output of each branch 380V7A/200V5A
Measuring Accuracy
Voltage: 1.0% Current: 1.0% Power factor: 1.0%
Reactive power: 2.0%
Function characteristic
1. Adopt AC sampling technology
2. Digital integration, filtration, not sensitive to theharmony wave.
3. Regard the reactive power as controlling physical quantity; it has highcontrol precision, without input and cutoff shaking.
4. The operation of the full digital of control parameter, easy to use, put inright place in one step, and the data are not lost to have a power failure.
5. Adopt and optimize the excellent control scheme automatically, reduce thetimes of input and cutoff, improve the service life of system.
6. Strong anti-interference ability can resist 2000V interference pulse frompower direct, and not crashing, does not lose the data, it is reliable to runsteady.
7. Digital display electric network power factors, reactive power, voltage,current (primary side) and control parameter.
8. With two working modes of manual and automatic is convenient for user toinstall and debug.
9. With the function of over-voltage, under-voltage judgment and display andfast cutoff capacitor group, prevent capacitor group from running under theover-voltage condition.
10. With the function of available input and cutoff shocking and locking(please indicate while or
during goods).
11. With the function for the delay time of the selectable single groupcapacitor for 200 seconds from cutoff to input, makes capacitor have abundantdischarging time after cutoff and reduce capacitor the impact in electric netwhen pouting into again (Please indicate while ordering goods).
12. The input resistance of current sampling signal is smaller than 0.05; itcan be taken out from measuring loops directly.
Output Loops: 1-12 Loop
RA-20 Series controller regards 8 single-chip microcomputer as core, adopt thecontrol scheme of phase splitting sampling and compensation and commoncompensation and phase splitting compensated altogether, very suitable forreactive compensation with 50Hz, 0.4KV three-phase load imbalance power system.
Technical Data
Basic Parameter
Rated voltage: AC 220V10% Rated current: AC 0-5ARated frequency: 50Hz5%
Control Parameter
Sensitivity: 100mA
COS Preset: 0.80-0.99; step length 0.01; Factorypreset 0.98 input and cutoff time
Delay: dynamic state 100ms-30S; Static state 1-250S; Factory preset dynamicstate 5S; static state 30S.
Over-voltage protection: 230-260V; step length 1V; Return difference 6V actor prest 240V,
Under-voltage protection:180V;return difference 6V
Auto Discriminating Phase: ON/OFF; factory preset ON(Auto discriminating ON)
Reactive threshold: OFF-4-100kvar; factory preset OFF (reactive thresholdinefficiency)
CT variation: 50/5A-3000/5A; step length 1; factory preset 500/5A
Capacitance capacity: 0-99kvar factory preset of each branch 10kvar
Contact capacity: dynamic state output of each branch DC12V50mA
Static state output of each branch 380V7A/200V5A
Measuring Accuracy
Voltage: 0.5% Current: 0.5% Power factor: 1.0%
Active power: 1.0%
Reactive power: 1.0%
Function characteristic
1. Liquid crystal display or LED shows three-phase voltage, current, activepower, reactive power, power, power, power factor and power network frequency,control parameter, etc..(Utilize this series of continue rollers to assemblethe capacitance case or compensator can save ampere meter, voltmeter, universalchange-over switch, etc.).
2. Strong anti-interference ability can resist 2000V interference pulse frompower direct, and not crashing, does not lose the data, it is reliable to runsteady.
3. Reactive power control physical quantity, high control precision;
4. The suer can revise the control parameteraccording to his own need, the control parameter isnot lost to have a power failure.
5. With automatic discriminating phase function (sampling signal automatic bekept in the same state).
6. The input resistance of current sampling signal is smaller than 0.05; itcan be taken out from measuring loops directly.
7. With over-voltage, under-voltage, imperfect phase protective function.
8. Compensation mode: phase splitting compensation, phase splittingcompensation and three-phase compensation, the three-phase compensation.
9. Output mode: static state, dynamic state, compound etc. Output loops 1-12 Loop
10. Size mounting hole:113113mm

- PS-1 Single Phase Watt-Hour Meter (Kilowatt Hour Meter) PS-1 Single Phase Watt-Hour Meter (Kilowatt Hour Meter)Single phase watt-hour meter is applicable for single phase active energy measurement. It

- PS-2 Single Phase Watt-Hour Meter PS-2 Single Phase Watt-Hour Meter The single phase watt-hour meter is applicablefor single phase active energy measurement. It is designed to meet IEC

- PS-3 Single Phase Electromechanical Watt-Hour MeterPS-3 Single Phase Electromechanical Watt-Hour MeterThe single phase electromechanical watt-hour meter is designed to meetlatest IEC60521. With accurac

- PS-5 Single Phase Electromechanical Watt-Hour MeterPS-5 Single Phase Electromechanical Watt-Hour MeterThe single phase electromechanical watt-hour meter is designed to meetthe IEC60521-1988 and BS EN 6

- PS-6 Single Phase Static Watt-Hour MeterPS-6Single Phase Static Watt-Hour MeterThe single phase static watt-hour meter isdesigned for measuring active energy in single-phase alternating curr


United Kingdom


English
Español
Русский