- Panel Meter
- Digital Multimeter
- PT-2 Three Phase Electromechanical Watt-Hour Meter
- PT-1 Three Phase Electromechanical Watt-Hour Meter
- PS-8 Single Phase Prepaid Electronic Meter - KWH Meter
- PS-7 Single Phase Multi-function Watt-Hour Meter
- PS-6 Single Phase Static Watt-Hour Meter
- PS-5 Single Phase Electromechanical Watt-Hour Meter
- PS-3 Single Phase Electromechanical Watt-Hour Meter
- PS-2 Single Phase Watt-Hour Meter
- Panel Meter
- Digital Multimeter
- PSA-5 Single Phase Electronic KWH Meter
- PSA-3 Single Phase Electronic KWH Meter
- PTA-2 Three Phase Electronic Multi-rate Watt-Hour Meter
- PSA-9 Single Phase Electronic Multi-rate Watt-Hour Meter
- PTA-1 Three Phase Electronic Watt-Hour Meter
- PSA-2 Single Phase DIN-rail Watt-Hour Meter
- PSA-1 Single Phase Electronic Watt-Hour Meter
- PT-6 Three Phase Electronic Prepaid Watt-Hour Meter
- PT-5 Three Phase Static Multi-function Energy Meter
- PT-3 Three Phase Static Active Watt-Hour Meter
- PT-2 Three Phase Electromechanical Watt-Hour Meter
- PT-1 Three Phase Electromechanical Watt-Hour Meter
- PS-8 Single Phase Prepaid Electronic Meter - KWH Meter
- PS-7 Single Phase Multi-function Watt-Hour Meter
- PS-6 Single Phase Static Watt-Hour Meter
- PS-5 Single Phase Electromechanical Watt-Hour Meter
- PS-3 Single Phase Electromechanical Watt-Hour Meter
- PS-2 Single Phase Watt-Hour Meter
- PS-1 Single Phase Watt-Hour Meter (Kilowatt Hour Meter)
- RA-2 Reactive Auto-compensation Power Controller
- RA-1 Reactive Auto-compensation Power Controller
- Low Voltage Power Capacitor
- TF Full Film Type H.V. Power Capacitor
- SH Self Healing Low Voltage Capacitor
- Power Capacitor / Power Controller
- Single Phase Watt-Hour Meter / KWH Meter (Kilowatt Hour Meter)
PSA-5 Single Phase Electronic KWH Meter
PSA-5Single Phase Electronic KWH Meter
Description
The single phase electronic KWH meter adoptsspecial Large-scale integration circuit, has the characteristics of fewperipheral elements, simple structure, high reliability, low power loss, longlife-span, which is the single phase AC power electric meter and the referencefrequency is 60 Hz.
Applications
The meter can be installed indoor or outdoor, adapt to the environmenttemperature is -10~+60, relative humidity is less than 80%. Allthe capability and specification is in accordance with all the technicalrequirements of ANSI12.1 standards, especially for single phase electronicmeter.
Characteristics
1. Using the latest electric integrate circuit compacted with innerdigital multiplier, greatly improve the dynamic working range, enlarge the overloading capability several times more.
2. All the elements of the meter is ling life-span and highly reliable.
3. Precise unidirectional measurement of the active energy, long service timewithout calibration.
4. Impulse output indicating when the meter is working.
5. Expandable infrared communication or RS-485 communication function.
6. High Electro-Magnetic Compatibility and anti-tampering function with LEDindicator.
7. Adopting Mechanism register to display the KWH clearly and straightly;step-upon electric motor with shielding cover, good anti-jamming capability;LCD displaying module is selective.
8. Good Measurement characteristic, working under the condition of variety ofpower factor all complied with flat and suitable load curve.
9. Low power loss designing, power loss is not more than 1W.
10. Wide voltage range designing, make sure the meter can work normally between0.7UN~1.2UN.
11. The meter cover and base is made of bakelite, PC, ABS etc., in accordancewith Type insulation protection requirements, good anti-inflammation andinsulation capability, firm structure and nice appearance.
Main TechnicianParameters
Meter Type: PSA-5
Connection: Socket Type
Reference Voltage: 120V~480V
Basic Current: 10(60)A, 15(100)A, 30(200)A
Reference frequency: 50Hz 60Hz
Accuracy: Class0.5 Class1 Class2
Starting Current: 0.4%Ib(Class 1) 0.5%Ib(Class 2)
Running with no-load: Logic design for running with no-load
Power Loss: 1W/6VA
Working condition: Standard working condition: -10~60
Relative Humidity80%
Working principle
The single phase electronic kWh meters adopts special Large-scale integrationcircuit to measure the KWH(Indicated by the broken line of the picture). Themeasurement of the KWH consumed by the users, through the sampling of thesignal by the voltage separator circuit and the shunt, processing the A/Dconverting procedure, the digital signal which is processed by the multiplierwould be sent to the D/F converter, the impulse which is output by theconverter circuit would drive the register to get the accumulated KWH, displaythe electricity consumption velocity by the KWH indicator.
Structure
The meter shell is composed of meter base, holder and transparent cover; Leadsealing is put between the cover and the base.

- Digital MultimeterDigital MultimeterDigital Multimeter DM-13 3 /4 digits LCD with a Max. readingof 3999.Low battery indicationOverload protectionSafely 500V CAT Accesso

- Panel MeterPanel MeterModel: PM-96. PM-72. PM-48. PM-A96. PM-A72. PM-A48Class: 1.5Specs: 0.1A, 0.5A, 1A, 1.5A,3A, 5A, 7.5A,10A, 15A, 20A,25A, 30A, 50A,75. 100A (

- PS-2 Single Phase Watt-Hour Meter PS-2 Single Phase Watt-Hour Meter The single phase watt-hour meter is applicable for single phase active energy measurement. It is

- PS-3 Single Phase Electromechanical Watt-Hour Meter PS-3 Single Phase Electromechanical Watt-Hour Meter The single phase electromechanical watt-hour meter is designed to meet latest

- PS-5 Single Phase Electromechanical Watt-Hour Meter PS-5 Single Phase Electromechanical Watt-Hour Meter The single phase electromechanical watt-hour meter is designed to meet the IEC


United Kingdom


English
Español
Русский