- Panel Meter
- Digital Multimeter
- PT-2 Three Phase Electromechanical Watt-Hour Meter
- PT-1 Three Phase Electromechanical Watt-Hour Meter
- PS-8 Single Phase Prepaid Electronic Meter - KWH Meter
- PS-7 Single Phase Multi-function Watt-Hour Meter
- PS-6 Single Phase Static Watt-Hour Meter
- PS-5 Single Phase Electromechanical Watt-Hour Meter
- PS-3 Single Phase Electromechanical Watt-Hour Meter
- PS-2 Single Phase Watt-Hour Meter
- Panel Meter
- Digital Multimeter
- PSA-5 Single Phase Electronic KWH Meter
- PSA-3 Single Phase Electronic KWH Meter
- PTA-2 Three Phase Electronic Multi-rate Watt-Hour Meter
- PSA-9 Single Phase Electronic Multi-rate Watt-Hour Meter
- PTA-1 Three Phase Electronic Watt-Hour Meter
- PSA-2 Single Phase DIN-rail Watt-Hour Meter
- PSA-1 Single Phase Electronic Watt-Hour Meter
- PT-6 Three Phase Electronic Prepaid Watt-Hour Meter
- PT-5 Three Phase Static Multi-function Energy Meter
- PT-3 Three Phase Static Active Watt-Hour Meter
- PT-2 Three Phase Electromechanical Watt-Hour Meter
- PT-1 Three Phase Electromechanical Watt-Hour Meter
- PS-8 Single Phase Prepaid Electronic Meter - KWH Meter
- PS-7 Single Phase Multi-function Watt-Hour Meter
- PS-6 Single Phase Static Watt-Hour Meter
- PS-5 Single Phase Electromechanical Watt-Hour Meter
- PS-3 Single Phase Electromechanical Watt-Hour Meter
- PS-2 Single Phase Watt-Hour Meter
- PS-1 Single Phase Watt-Hour Meter (Kilowatt Hour Meter)
- RA-2 Reactive Auto-compensation Power Controller
- RA-1 Reactive Auto-compensation Power Controller
- Low Voltage Power Capacitor
- TF Full Film Type H.V. Power Capacitor
- SH Self Healing Low Voltage Capacitor
- Power Capacitor / Power Controller
- Single Phase Watt-Hour Meter / KWH Meter (Kilowatt Hour Meter)
PS-5 Single Phase Electromechanical Watt-Hour Meter
PS-5 Single Phase Electromechanical Watt-Hour Meter
The single phase electromechanical watt-hour meter is designed to meetthe IEC60521-1988 and BS EN 60521 standards for both indoor and outdoorinstallations. The meter with mechanical construction complying BS5685 is alsoavailable. With accuracy of class 2, it measures active energy in single-phasetwo-wire or three-wire alternating current power grids.
Features
1. Connection is direct or by instrument transformers.
2. The average service life (MTTF)is 10 years and themaximum overload capacity is 500%lb.
3. The meter is KEMA certified and the design can be tailored to differentcustomer requirements.
Components of Single Phase Watt-Hour Meter
1. Metercase
Two types of cases are available One is the insulating case ofprotective-class and the other is the weather-proof case complying to IEC60529 and Ip54
2. Terminal block
The terminal block is molded of bakelite. The voltage test link can be locatedinside or out-side of the meter case. The maximum diameter of the terminal holeis 8.5mm.
3. Driving element
The driving element consists of a voltage element anda current element, both of which are fixed to the frame. The voltage elementhas a low load adjustment mechanism, and the current
element has an inductive load adjustment mechanism.
4. Rotor
The rotor shaft is made of aluminum alloy with a small hole in the upper endfor storing lubrication and for fitting a brass bearing Theworm is turned of brass, and is acid-cleaned or nickel-plated.
The worm and shaft can be detached.
5. Braking element
The magnet is made of AINiCo5 alloy and designed asU-shaped so that the effect of short-time over current upon the magnet isnegligible. The full load error can be fine controlled by adjustment mechanism.
6. Frame
The frame is die-casted by high-quality SiAl alloy of stable property to avoid distortion. Theapplication of static spray-painting on the surface prevents the frame fromoxidation.
7. Upper bearing
The pin is made of high-quality abrasion-proofstainless steel and is embedded on the brass pin base.
8. Lower bearing
Both double jewel bearing and magnetic bearing areavailable.
9. Register
The meter with direct-reading cyclometer type register is available.
The register is self-located and is mounted on the frame by one screw. Fixingwith two screws is also available but needs to be manually adjusted. There aretwo types of gears available: brass gears and self-lubricating plastic gears.
TypicalConnection Diagram of Single Phase Watt-Hour Meter
Outline & Installation Size
Technical Parameters of Single Phase Watt-Hour Meter
| 1 | Meter type | PS-5 |
| 2 | Applicable Standards | IEC60521. IEC514 |
| 3 | Accuracy | Class 2 (according to IEC60521) |
| 4 | Average service life (MTTF) | 10years |
| 5 | Basic current (lb) A | 1.5 2.5 3 5 10 15 20 30 |
| 6 | Maximum current (lmax) A | 6 10 12 20 40 50 60 80 100 |
| 7 | Rating current of transformer in | 5A Direct connection |
| 8 | Reference voltage Un | 110V,120V,220V,230V,240V |
| 9 | Reference frequency fn | 50Hz,60Hz |
| 10 | Power losses in voltage circuit at Un | 50Hz: 1.2W/6VA, 60Hz: 1.0W/5VA |
| 11 | Power losses in current circuit at 50Hz Un Ib | <0.6VA |
| 12 | Non-running with no-load | 0.8~1.1Un |
| 13 | Starting current | 0.5%lb |
| 14 | Mean temperature coefficient: Form0.1lb to lmax at unity PF Form 0.2lb to lmax at unity 0.5lagging | <0.08%/ <0.12%/ |
| 15 | Insulation level: Withstanding A.C. voltage for 50Az, 1min Withstanding impulse voltage 1.2/50us | >2kV(when bakelite base>4kV) >6KV(when bakelite base>8kV) |
| 16 | Rated load speed at unity PF, lb | 13.2r/min |
| 17 | Rated load torque at unity PF, lb | 450uNm |
| 18 | Weight of rotor | 24g |
| 19 | Weight of meter | 1.5~1.6kg |
| 20 | Meter base | Steel, Aluminum alloy, Bakelite |
| 21 | Meter cover | ABS, Aluminum, Glass, Bakelite, transparent PC |
| 22 | Terminal cover | ABS, Bakelite, PC |
| 23 | Register | Cyclometer single, Unidirectional, Jumping , Metal |
| 24 | Option | Reverse running stopper, pulse sampling device |

- PS-6 Single Phase Static Watt-Hour MeterPS-6Single Phase Static Watt-Hour MeterThe single phase static watt-hour meter isdesigned for measuring active energy in single-phase alternating curr

- PS-7 Single Phase Multi-function Watt-Hour Meter PS-7 Single Phase Multi-function Watt-Hour Meter The single phase multi-function watt-hourmeter, a type of fully electronic active energy electricitym

- PS-8 Single Phase Prepaid Electronic Meter - KWH MeterPS-8 Single Phase Prepaid Electronic Meter - KWH MeterDescription The single phase prepaid electronic meter, briefly named as single-phaseintelligent

- PT-1 Three Phase Electromechanical Watt-Hour Meter PT-1 Three Phase Electromechanical Watt-Hour Meter Description The three phase electromechanical watt-hour meter is designed to meet thelatest IEC6052

- PT-2 Three Phase Electromechanical Watt-Hour Meter PT-2Three Phase Electromechanical Watt-Hour MeterGeneralIntroduction The three phase four-wire electromechanicalwatt-hour meter is designed to meet th


United Kingdom


English
Español
Русский