- TNS Series AC Automatic Voltage Regulator 15-90KVA
- TNS Series AC Automatic Voltage Regulator 1.5-9KVA
- HZ4832 Semiconductor Curve Tracer
- ST16/ HZ4318 /4338 Oscilloscope
- Full Auto Battery Charger
- GCA Series Battery Charger
- Battery Charger
- DC Power Supply
- SKN-Z Series Pure Sine Wave Inverter
- Low Frequency Home Inverter
- DA Series Solar Inverter
- SK Series Solar Inverter
- IPS (Inverter for Power Supply)
- SKN-H Series High Frequency Home Inverter
- EPS Series Intelligent Pure Sine Wave Inverter
- Car Inverter
- TXB series Line-interactive UPS
- SKG Series 6-20KVA Online UPS
- SKG Series 1-3KVA LCD Display Online UPS
- SP Series Working Frequency On-Line UPS
- PCS Series Line-Interactive UPS
- PCN-V Series Line-Interactive UPS
- PCM Series Off-Line UPS
- UPS (Uninterruptible Power Supply )
- AVR (Automatic Voltage Regulator)
- SVC Series AC Automatic Voltage Regulator
- PCH Series Off-Line UPS
- PCD Series Off-Line UPS
- SPR Series LED Display Regulator
- SCR Series LED Display Regulator
- SBW Series AC Automatic Voltage Regulator
- TNS Series AC Automatic Voltage Regulator
- TMK Series AC Automatic Voltage Regulator
- SMR Series AC Automatic Voltage Regulator
- SVR Series AC Automatic Voltage Regulator
- SVB Series AC Automatic Voltage Regulator / SVB Inverter
- SKG Series 1-3KVA LED Display Online UPS
- TXD Series UPS
- SBW20-250KVA AC Automatic Voltage Regulator
- SBW20-150KVA AC Automatic Voltage Regulator ( LCD display)
- SBW300-2000KVA AC Automatic Voltage Regulator
- TXA-Q series Off-line UPS
- TXC series Line-interactive UPS
- TXA series Off-line UPS
- TXF Series UPS
- SVC Series AC Automatic Voltage Regulator 5-10KVA
- SVC Series AC Automatic Voltage Regulator 0.5-30KVA
- SVC Series AC Automatic Voltage Regulator 15-30KVA
- Oscilloscope & Semiconductor Curve Tracer
- TXE Series UPS
PCS Series Line-Interactive UPS
PCS Series Line-Interactive UPS
Main Features of Line-InteractiveUninterruptible Power Supply
1.With CPU control, theline-interactive UPS can supportautomatic restart.High or lowvoltage protection, overload or short protectionis ensured. c
2. It has wide input voltage range.
3. Cool start computer even there isnt mainpower
4. Automatic recharge even UPS isoff
5. With intelligent battery management, there will be beeping alarm on battery,when the battery is low and overload. Also the beeping isselectable.
6. Smart RS232, RJ11, USBis optional.
Technical Parameters
| Product | Requirements | Model 1 | Model 2 | Model 3 | Model 4 | Model 5 | Model 6 | Model 7 |
| Power (VA) | PCS-400 | PCS-500 | PCS-650 | PCS-800 | PCS-1000 | PCS-1200 | PCS-1500 | |
| Input | Voltage | 145-290VAC5V | ||||||
| Frequency | 50Hz+/-10% | |||||||
| Output | Voltage (AC Mode) | 190-250VAC | ||||||
| Voltage (Inverter Mode) | 220VAC 5% | |||||||
| Capacity | 400VA/240W | 500VA/300W | 650VA/360W | 800VA/480W | 1000VA/600W | 1200VA | 1500VA | |
| Frequency (Inverter Mode) | 50Hz+/-0.5Hz | |||||||
| Transfer Time | 6MS | |||||||
| Generator connection | Normal Working under the Generator | |||||||
| Waveform | modified-Sine wave | |||||||
| Protection | Spike & Surge Suppression | yes | ||||||
| Over/Under Volt. | Switch to Bat. O / P when Mains over regulation range | |||||||
| Over load /short Circuit | Fuse & current limited for both Mains and Battery modes | |||||||
| Battery | Type | Lead-Acid maintenance-free | ||||||
| Dc Bus | 12V4.5Ah | 12V7.0Ah | 12V9.0Ah | 12V7.0Ah | 12V9.0Ah | |||
| Number | 1PC | 1 PC | 2 PCS | |||||
| Recharge time | 8hours90% | |||||||
| Back up time(one PC) | 5-10mins | 8-15mins | 10-18mins | 15-25mins | 20-30mins | 20-30mins | 25-45mins | |
| Physical | Weight (KGs) | 4.5 | 5 | 5.5 | 6.5 | 10.5 | 11 | 11.5 |
| Shipping Wt. | 5 | 5.6 | 6 | 7 | 11 | 11.5 | 12 | |
| Product Dimensions (mm) | 335*95*160 | 355*120*195 | ||||||
| Packing Dimensions (mm) | 375*170*200 | 420*190*250 | ||||||
| Soft ware | RS232 or USB option Windows & NT | Auto save & shut down | ||||||
| Function | Cold start | UPS Start The Computer Even there Is no Main Power | ||||||
| Automatic Charge | Automatic Charge when UPS is off | |||||||
| Automatic Restart | Automatic Restart if main power coming within one hour(UPS shutdown by Automatic) | |||||||
| Voltage display | 220v/230v Optional following the real capacity | |||||||
| Frequency | 50HZ/60HZ Optional following the real | |||||||
| Beeping | During the battery mode ,the beeping optional | |||||||
| Efficiency | AC-AC | 1 | ||||||
| DC-AC | 0.6 | |||||||
| Acoustic | Noise level | 45dB | ||||||
| Environmental | Temperature | -5-45 Degree C | ||||||
| Humidity | 20% to 90% | |||||||
| Power Outlets | No. and types | 2 Sockets | 3 Sockets | |||||
TianXin Electrical Co., Ltd. is a leading internationalmanufacturer of high quality power supply testing equipment, located in China. At TianXin, we can supply you high quality power supplytesting equipment such as AC automatic voltage regulator, uninterruptible powersupply, solar inverter, DC power supply and batterycharger.

- SP Series Working Frequency On-Line UPSSP Series Working Frequency On-Line UPSMain Functions of SP Series On-Line UninterruptiblePower Supply (UPS)1. The On-lineuninterruptible power supply

- SKG Series 1-3KVA LCD Display Online UPSSKG Series 1-3KVA LCD Display Online UPSThe high frequency LCD display online uninterruptible power supply can be usedfor small network servers and ot

- SKG Series 6-20KVA Online UPSSKG Series 6-20KVA Online UPSFeatures of High Frequency OnlineUninterruptible Power Supply1) Adopts high frequencyand double conversion on-line techno

- TXB series Line-interactive UPS TXB series Line-interactive UPSMain Features1. The line-interactiveUPS adopts CPU control.2. Wide input voltage and frequency range is ensured. 3. Hig

- Car Inverter CarInverterMain Functions 1. Low voltage alarm andshutdown.2. Over voltageshutdown.3. Over load protect.4. Short-circuitprotect.5. Over heatprotect.6.


United Kingdom


English
Русский