- Intercooler
- Ammonia Liquid Separator
- Ammonia Liquid Receiver
- Ammonia Oil Separator
- Thermosiphon Liquid Receiver
- Air Separator
- SCF Closed Circuit Cooling Tower
- Closed Circuit Cooling Tower
- Evaporative Condenser
- SMF Closed Circuit Cooling Tower
- Shell and Tube Heat Exchanger
- SWLN Evaporative Condenser
- SWL Evaporative Condenser
- Aroma Compatible Ink Cartridge
- Large Format Ink Cartridge
- Refillable Cartridge for HP Printer
- Oil Receiver
- Refillable Cartridge for Canon Printer
- Refillable Cartridge for Brother Printer
- Refillable Cartridge
- CISS for HP Printer
- CISS for Epson Printer
- CISS for Canon Printer
- CISS for Brother Printer
- Continuous Ink Supply System (CISS)
- ECO Solvent Ink
- Solvent Ink
- Pigment Ink
- Dye Ink
- Inkjet Printer Ink
- Portray Ink
- Optical Measurement Machine (CCD Camera)
SMF Closed Circuit Cooling Tower
SMF Closed Circuit Cooling Tower
1. Principle of Work
Developed on the basis of internationally advanced heat-exchange technology, SMF closed circuit cooling tower is a
piece of highly efficient heat exchange equipment.
The working fluid is flowing inside the coils, which are enwrapped by spray
water on the outside. The heat of water is transferred by coils and becomes the
saturated vapor when meets the water and air. The heat is exhausted out of the
cooling tower by the fan, and water is collected back to the bottom tank. The
spray water is cooled down via PVC radiation fin during the circulation process
and flows in the same direction with the fresh wind. The coil mainly takes
sensible heat travel style. This is especially suitable for cooling high temperature
fluid.
(1). The cooled circulating water helps increase the
temperature difference between the water and the warm process fluid, which
results in a smaller coil heat exchange size, fewer coil connections, and thus
reduced weight. This feature further reduces the
tendency to form scale on the coil since cooler water offers higher solubility
for scaling.
(2). Parallel air and water paths minimize scale-producing dry spots that may
be found on the bottom of tubes in conventional cooling towers.
(3). The coil section of the closed circuit cooling tower dissipates heat
through both evaporative cooling using the fresh air stream and, more
significantly through sensible heat cooling using the pre-cooled circulating
spray water. Reducing evaporative cooling from coils helps to minimize the
possibility of forming scale on the coil surface.
(4). The circulating spray water falls from the coil to PVC heat exchange
padding where it is cooled by second fresh air stream using both evaporative
and sensible heat transfer processes.
(5). Water is pumped over the evaporative coil surface area at 6.8l/m2 to ensure continuous wetting of the
primary heat transfer surface which enhances heat transfer efficiency and
minimizes fouling and scale formation.
2. Advantages
The closed circuit cooling tower provides many
operational and maintenance benefits to the user by keeping the process fluid
in a clean, closed loop.
(1). Protect process fluids from contamination.
(2). Maximize system
efficiency by reducing fouling.
(3). Reduce system energy costs.
(4).
Reduce system maintenance costs.
(5).
Provide reliable, efficient, year-round operation.
As a result, our SMF closed circuit cooling tower is a product of choice for
users.
3. Parameters of SMF Closed Circuit Cooling Tower
|
Model |
Nominal flow rate (m³/h) |
Fan power (kw) |
Air flow (m³/h) |
Water pump power (kw) |
Spray water (m³/h) |
Pipe-connecting size (mm) |
Approx. weight (kg) |
Dimensions L×W×H(mm) |
|
|
Shipping |
Operating |
||||||||
|
SMF-30 |
38 |
4 |
60000 |
1.5 |
45 |
65 (2) |
2950 |
3880 |
1850×2410×4225 |
|
SMF-40 |
46 |
5.5 |
65000 |
1.5 |
45 |
80 (2) |
3150 |
4290 |
1850×2410×4225 |
|
SMF-50 |
55 |
5.5 |
75000 |
1.5 |
45 |
80 (2) |
3680 |
5100 |
1950×3030×4265 |
|
SMF-60 |
67 |
7.5 |
75000 |
2.2 |
65 |
100 (2) |
3850 |
5500 |
1950×3030×4265 |
|
SMF-70 |
75 |
4(2) |
60000 (2) |
2.2 |
65 |
100 (2) |
4950 |
7980 |
3590×2410×4225 |
|
SMF-80 |
96 |
5.5(2) |
65000 (2) |
3 |
95 |
125 (2) |
5280 |
8250 |
3590×2410×4225 |
|
SMF-100 |
109 |
5.5(2) |
72000 (2) |
3 |
95 |
125 (2) |
5580 |
8900 |
3790×2610×4965 |
|
SMF-125 |
135 |
7.5(2) |
75000 (2) |
4 |
125 |
150 (2) |
5750 |
9100 |
3790×2610×4965 |
|
SMF-150 |
156 |
7.5(2) |
87000 (2) |
4 |
125 |
150 (2) |
6550 |
9850 |
3790×3030×4965 |
|
SMF-175 |
182 |
5.5(3) |
65000 (3) |
5.5 |
165 |
175 (2) |
6890 |
10900 |
5330×2410×4825 |
|
SMF-200 |
211 |
7.5(3) |
75000 (3) |
5.5 |
165 |
175 (2) |
7350 |
11200 |
5330×2410×4825 |
|
SMF-250 |
260 |
7.5(3) |
87000 (3) |
7.5 |
210 |
200 (2) |
8860 |
12100 |
5630×2610×4965 |
|
SMF-300 |
315 |
11(3) |
125000 (3) |
7.5 |
210 |
175 (4) |
10600 |
14100 |
6000×3200×4965 |
|
SMF-350 |
359 |
7.5(4) |
100000 (4) |
5.5 (2) |
165 (2) |
175 (4) |
12500 |
17800 |
8050×3200×4965 |
|
SMF-400 |
412 |
11(4) |
125000 (4) |
5.5 (3) |
165 (2) |
175 (4) |
13900 |
19900 |
8050×3500×4965 |
|
SMF-500 |
522 |
7.5(6) |
87000 (6) |
7.5 (2) |
210 (2) |
200 (4) |
16900 |
23900 |
5630×5250×4965 |
4. Engineering Considerations
Location Requirement
SMF closed circuit cooling tower must have an adequate supply of fresh air to all air inlets. When units are located adjacent to building walls or in enclosures, care must be taken to ensure that the warm, saturated discharge air is not deflected and drawn back to the air inlets.
For detailed recommendations on Wan Xiang closed circuit cooling tower layout, please contact us our technical department.
Think about the Compatibility of Fluid
The fluid to be cooled must be compatible with the coil material. Fluids not compatible with coil materials can lead to coil corrosion and failure. Certain fluids may require occasional pressure cleaning or mechanical cleaning of the inside of coil. In such cases, the coil must be designed to provide this capability.
Piping and Valves
Piping size and installation must be in accordance with good piping criterion. All piping should be supported by pipe hangers or other supports, not by the closed circuit cooling tower. External shut off valves may also be required if the system design necessitates the isolation of individual tower cells.
Capacity ControlIn general seasons,
the performance of most closed circuit cooling tower will vary due to the
change of its environmental wet bulb temperature. Therefore, when the change of
environmental temperature leads to the difference of liquid temperature, in
this case, capacity control will be required.
Fan periodicity operation is the simplest method of capacity control for our
closed circuit cooling towers, normally used in multi fan unit system or multi
cell unit system. In some circumstances of low requirement on outlet water
temperature control, fan periodicity operation can meet with temperature
control requirement, and also, is easy to handle. Using two-speed fan can provide
substantial energy savings when compared to simple fan periodicity operation.
Protection against Coil Freezing
At below freezing ambient temperatures, the closed circuit cooling tower can experience heat loss even when the circulating spray water pump and fans are not operating. Without a heat load on the circulating fluid, coil freezing can occur even at full flow. Protective measures are readily available to avoid potential freezing problems. Where the system will permit, the best protection against coil freezing is the use of an anti-freeze solution. When this is not possible, the system must be designed to meet the following conditions: Maintain a heat load on the circulating fluid so that the temperature of the fluid leaving the coil will not fall below7℃.
Attached: Mixture Ratio of Antifreeze Liquid (For example glycol)|
Glycol (wt %) |
0 |
10 |
20 |
30 |
40 |
50 |
58 |
80 |
90 |
|
Freezing point (℃) |
-0.0 |
-3.5 |
-8 |
-15 |
-24 |
-36 |
-48 |
-47 |
-29 |
5.
High Quality Parts
(1) Imported Galvanized Steel Sheet
The shell of the
cooling tower uses imported galvanized steel sheet, which offers great
corrosion resistance, heat resistance and aesthetic appearance. In addition,
the galvanized steel sheet lasts 3-6 times longer than ordinary galvanized
plates.
(2) Electronic Scaling Apparatus
The enclosed circuit cooling tower is
equipped with advanced electronic scaling apparatus, which can do antiscale, contaminant
separation, sterilization and algae removal through the use of electronic pulse
technique. The only thing you need to do is Connect 220V power, and then it
will deal with the recycled water, which effectively prevents the formation of
dirt on both coil walls and padding.
(3) Circulating Water Pump
The circulating water pump uses quality mechanical seal that is not restricted
by the direction of rotation. It offers long lifetime, no leakage, low
power, high flow rate, low noise, and other advantages.
(4) Propeller Fan
The ventilation system uses a special propeller fan with aluminum alloy
blade, featuring front tipping blades, streamlined entrance wind-cone,
nor-pulley driven structural design and totally enclosed self-cooled motor with
low noise. It has such advantages as light weight, small size, good starting
performance, reliable operation and high durability.
(5) Heat Exchange Coils
The forward flow type coils are made of
high-quality steel pipes; counter flow type coils are made of quality
elliptical steel pipes. The design pressure is 2.0MPa. In order to ensure 100%
qualified welding quality, 2.0MPa airproof tests are conducted at coil-shaping
stage and assembly stage, and the whole pipe bundle has undergone a hot-dip
galvanizing treatment.
(6) Water Dispatching System
The cooling water spray system uses high-flow-rate and ant-clogging
basket type nozzle to ensure water can be continuously sprayed on the
components of the coil. Under the help of induced air, water can thoroughly
cover all the coils to facilitate the complete heat exchange among water, air
and refrigerant. In this case, heat transfer efficiency will increase
dramatically. The nozzle is connected on spray pipe branch, which can be easily
removed for convenient cleaning.
(7) Dismountable Water Dehydrator
The dehydrator of the cooling tower is made of corrosion resistant PVC
material. The special structure can get rid of the humid air moisture coming
out from the coil pipe by means of changing the air current 3 times, making the
water leakage rate as low as 0.001%. It is very convenient to disconnect the
dehydrator when we do the cleaning.
(8) PVC Padding Heat Exchange Layer
SMF closed circuit cooling towers adopt
PVC honeycomb type padding. The short horizontal air-inlet design can help the
cool air and water do heat exchange to the utmost extent. In addition, the
padding can bear the water up to 68℃, and has the advantages of good flame-retardant
performance, ageing resistance, deformation resistance and low wind resistance
coefficient, etc.
6. Warranties
When purchasing our SMF closed circuit cooling tower, please refer to applicable and effective warranties as well as the restrictions.
Wanxiang is a specialized closed circuit cooling tower manufacturer based in China. Our company offers a wide range of products, including a closed circuit cooling tower, thermosiphon dry-mode evaporator, evaporative condenser, and more.

- Evaporative Condenser Evaporative Condenser Wanxiang is a professional evaporative condenser manufacturer in China. We offer evaporative condenser, clo

- Closed Circuit Cooling Tower Closed Circuit Cooling Tower Our company is a professional closed circuit cooling tower manufacturer and supplier in China.

- SCF Closed Circuit Cooling Tower SCF Closed Circuit Cooling Tower 1. Principle of Work SCF closed circuit cooling tower is a piece of highly effi

- Air Separator Air Separator 1. Product Description The air separator is used to separate non-condensable gas from ammonia gas a

- Thermosiphon Liquid Receiver Thermosiphon Liquid Receiver 1. Design Parameters Design pressure: 2.0MPa Water pressure test: 2.5MPa Medium: ammon


United Kingdom


English
Français
Español
Русский
العرب
Português

