- Inverter
- Gallery
- Principle,Wiring
- Technical Parameters
- Gallery
- Physical Features
- Physical Features
- Technical Parameters
- Principle,Wiring
- Applications
- CATV UPS, EX-0614
- DC Axial UPS Cooling Fan
- UPS Cooling Fan
- 10-20kVA UPS
- 20kVA UPS and UPS higher than 20kVA
- 6-10kVA UPS
- 1-3kVA UPS
- 500VA-1200VA UPS
- HW9110E High Performance Integrated Outdoor Online UPS, 1kVA-10kVA
- GM Series 6 - 20kVA
- G Series 1 - 3kVA
- GM Series 6 - 20kVA
- G Series 1 - 3kVA
- LG Series 500-1200VA
- ST Series 1 - 3kVA
- HP9330C Series 10 - 80kVA
- GP Series 10 - 200kVA
- GP Series 6 - 30kVA
- HP9116C & HP9316C Series 6-20kVA UPS
- HP9116C Series 1 - 3kVA
- B Series 500-1200VA
- ST Series 1 - 3kVA
- HP9117C series1 - 3kVA
- GP series 10-200kVA UPS
- GP series 6-30kVA UPS
- HP9330C Series 10 - 80kVA
- HP9116CR & HP9316CR series 1-10kVA UPS
- HP9116C & HP9316C Series 6-20kVA UPS
- HP9116C Series 1 - 3kVA
- G / GM Series 6 - 20kVA
- G / GM Series 1 - 3kVA
- ST Series 1 - 3kVA
- GP series 10-200kVA UPS
- GP series 6-30kVA UPS
- HP9330C series 20-80kVA UPS
- HP9116CR & HP9316CR series 1-10kVA UPS
- HP9116C & HP9316C series 6-20kVA UPS
- HP9116C Series 1-3kVA UPS
- G-GM series 6-20kVA UPS
- G-GM Series 1-3kVA UPS
- Difference Between EPS and UPS
- Passive Power Filter
- Active Power Filter (APF)
- Power Filter
- UPS Cooling Fan
- UPS Battery Charger
- UPS SNMP Card
- Inverter UPS Accessories
- Lighting Power EPS (Emergency Power Supply)
- Lighting EPS (Emergency Power Supply)
- EPS (Emergency Power Supply)
- UPS System
- LED UPS
- LCD UPS
- Low Frequency Online UPS
- High Frequency Online UPS
- ST Series 1-3kVA UPS
- HP9117C Series 1-3kVA UPS
- Online UPS
- UPS (Uninterruptible Power Supply)
- Off Line UPS
HP9116C & HP9316C series 6-20kVA UPS
Applications of HP9116C & HP9316C series 6-20kVA UPS
HP9116C & HP9316C series 6-20kVA is quite suitable for servers, data centers, critical network devices, sensitive electronic equipment, telecommunications, etc.
Features of HP9116C & HP9316C series 6-20kVA UPS
1. Designed with true on-line double conversion technology, and employs advanced microprocessor control.
2. Wide input voltage.
3. Zero transfer time.
4. Protection against all types of power problems.
5. No add-on CNTL unit required for parallel connection.
6. Site wiring fault warning.
7. Low initial investment and flexible for future expansion.
8. Good reliability and performance for power sharing and redundancy.
9. Equipped with maintenance bypass switch.
10. Smart RS232 communication interface.
11. Intelligent slot is available.
12. Sealed, lead-acid, and maintenance free battery.
Features
1. Adopts LCD to display the detailed real-time UPS status.
2. Microprocessor control guarantees high reliability.
3. Equipped with boost and buck AVR to stabilize input voltage.
4. Built-in DC start function is designed to start UPS while AC power supply is unavailable.
5. HP9116C & HP9316C series UPS products are installed with smart RS-232 communication port. You can download software from the internet.
6. User-replaceable battery design.
7. Auto charge even though UPS is off.
8. Auto restart while AC recovery.
9. Provides modem or phone line surge protection.
10. Provides discharge, overcharge, and overload protection.
11. USB port is available upon request.
Technical Specifications
| Product series | HP9116C 6 - 10kVA (1 PH / 1 PH) | HP9316C 10 - 20kVA (3PH / 1PH) | ||||||
| Model number | 6KT | 10KT | 6KT-XL | 10KT-XL | 10KT-XL | 15KT-XL | 20KT-XL | |
| Rated power | Volt-amps/Watts | 6kVA/ 4.2KW | 10kVA/ 8KW | 6kVA/ 4.2KW | 10kVA/ 7KW | 10Kva/ 7KW | 15Kva/ 10.5KW | 20Kva/ 14KW |
| Input | Low line transfer | 176VAC 3VAC | 304VAC 3VAC | |||||
| Low line comeback | 185VAC 3VAC | 322VAC 3VAC | ||||||
| High line transfer | 276VAC 3VAC | 478VAC 3VAC | ||||||
| High line comeback | 266VAC 3VAC | 461VAC 3VAC | ||||||
| Frequency range | 50Hz, 46-54Hz, 60Hz, 56-64Hz. | |||||||
| Power factor | 0.98 | 0.95 | ||||||
| Phase | Single Phase with ground | Three phase (4 Wires ground) | ||||||
| Connection | Hardwired | |||||||
| Output | Voltage | 220VAC or 230VAC or 240VAC | ||||||
| Voltage regulation | 1% | |||||||
| Frequency | Synchronization range (line mode); 50 or 60Hz (1 0.05% ) Hz (battery mode) | |||||||
| Power factor | 0.7 or 0.8 | |||||||
| Wave form | Pure sine wave | |||||||
| Phase | Single phase | |||||||
| Voltage distortion | 2% THD (linear load), 6% THD (non - linear load) | |||||||
| Overload capability | 105%~130% for 10 min., more than 130% for 1 second | |||||||
| Current crest ratio | 3:1 max | |||||||
| Connection | Hardwired | |||||||
| Battery | Type | Valve regulated, sealed, lead-acid | External battery bank | |||||
| Nominal DC voltage | 240VDC | |||||||
| Backup time (full load) | 7 min | 5 min | Depends on the external battery capacity | |||||
| Recharge time | 7 hours to 90% | 8 hours to 90% | Depends on the external battery capacity | |||||
| Charge current (max.) | 2A | 4.2A | ||||||
| Charge voltage | 274Vdc 1V | |||||||
| Transfer time | AC to DC | 0 ms | ||||||
| Inverter to bypass | 2.5 ms (typical) | |||||||
| Indicators | Status | Load level / battery level, battery, utility power, inverter, bypass, overload, fault. | ||||||
| Audible alarm | Bypass | Alarm beeps every two seconds | ||||||
| Battery discharge | Alarm beeps every four seconds. Alarm beeps every one second if battery capacity is low. | |||||||
| Overload | Alarm beeps twice every one second | |||||||
| Fault | Alarm beeps continuously | |||||||
| Maintenance bypass switch | Yes | |||||||
| Communications interface | DB-9 Port | RS-232 serial interface | ||||||
| Intelligent slot | Options: SNMP card, AS400 card or Win power CMC / (USB port) | |||||||
| Parallel port | Availability of up to three units in parallel for power redundancy and load sharing | |||||||
| Environment | Operating temperature | 0 ~ 40 | ||||||
| Operating humidity | 20 ~ 90% non-condensing | |||||||
| Noise level | Less than 55dB@1 meter | Less than 60dB@1 meter | ||||||
| Physical feature | Weight net (Kg) | 90 | 93 | 35 | 38 | 39 | 55 | |
| Body size WDH (mm) | 260570717 | |||||||

- HP9116CR & HP9316CR series 1-10kVA UPS HP9116CR & HP9316CR series 1-10kVA UPSApplication of HP9116CR & HP9316CR series Rack Mount Online UPSHP9116CR & HP9316CR series rack moun

- HP9330C series 20-80kVA UPS HP9330C series 20-80kVA UPSApplication of HP9330C series 20-80kVA UPSHP9330C series 20-80kVA UPS is particularly applicable to severs, data centers,

- GP series 6-30kVA UPS GP series 6-30kVA UPSOur GP series 6-30kVA UPS is composed of GP11 series UPS, GP911 series UPS, GP 31 series UPS, and GP931 series UPS. Among them,

- GP series 10-200kVA UPS GP series 10-200kVA UPSGP series 10-200kVA UPS products include GP33 series and GP933 series UPS. They are widely used in data management equipment a

- ST Series 1 - 3kVA ST Series 1 - 3kVA


United Kingdom


English
Español
Русский