- Inverter
- Gallery
- Principle,Wiring
- Technical Parameters
- Gallery
- Physical Features
- Physical Features
- Technical Parameters
- Principle,Wiring
- Applications
- CATV UPS, EX-0614
- DC Axial UPS Cooling Fan
- UPS Cooling Fan
- 10-20kVA UPS
- 20kVA UPS and UPS higher than 20kVA
- 6-10kVA UPS
- 1-3kVA UPS
- 500VA-1200VA UPS
- HW9110E High Performance Integrated Outdoor Online UPS, 1kVA-10kVA
- GM Series 6 - 20kVA
- G Series 1 - 3kVA
- GM Series 6 - 20kVA
- G Series 1 - 3kVA
- LG Series 500-1200VA
- ST Series 1 - 3kVA
- HP9330C Series 10 - 80kVA
- GP Series 10 - 200kVA
- GP Series 6 - 30kVA
- HP9116C & HP9316C Series 6-20kVA UPS
- HP9116C Series 1 - 3kVA
- B Series 500-1200VA
- ST Series 1 - 3kVA
- HP9117C series1 - 3kVA
- GP series 10-200kVA UPS
- GP series 6-30kVA UPS
- HP9330C Series 10 - 80kVA
- HP9116CR & HP9316CR series 1-10kVA UPS
- HP9116C & HP9316C Series 6-20kVA UPS
- HP9116C Series 1 - 3kVA
- G / GM Series 6 - 20kVA
- G / GM Series 1 - 3kVA
- ST Series 1 - 3kVA
- GP series 10-200kVA UPS
- GP series 6-30kVA UPS
- HP9330C series 20-80kVA UPS
- HP9116CR & HP9316CR series 1-10kVA UPS
- HP9116C & HP9316C series 6-20kVA UPS
- HP9116C Series 1-3kVA UPS
- G-GM series 6-20kVA UPS
- G-GM Series 1-3kVA UPS
- Difference Between EPS and UPS
- Passive Power Filter
- Active Power Filter (APF)
- Power Filter
- UPS Cooling Fan
- UPS Battery Charger
- UPS SNMP Card
- Inverter UPS Accessories
- Lighting Power EPS (Emergency Power Supply)
- Lighting EPS (Emergency Power Supply)
- EPS (Emergency Power Supply)
- UPS System
- LED UPS
- LCD UPS
- Low Frequency Online UPS
- High Frequency Online UPS
- ST Series 1-3kVA UPS
- HP9117C Series 1-3kVA UPS
- Online UPS
- UPS (Uninterruptible Power Supply)
- Off Line UPS
HP9116C Series 1-3kVA UPS
Applications of HP9116C Series 1-3kVA UPS
HP9116C Series 1-3kVA can be widely suitable for servers, data centers, critical network devices, sensitive electronic equipment, telecommunications, etc.
Features of HP9116C Series 1-3kVA UPS
1. HP9116C Series 1-3kVA is installed with a large blue back light LCD to display the detailed real-time UPS status.
2. Microprocessor control guarantees reliability.
3. Comprehensive self-protection design.
4. Audible alarm mute.
5. Cold start function.
6. Auto self-testing system while starting UPS.
7. Wide input voltage range.
8. USB port is available upon request.
Technical Specifications
| Product series | Online UPS with large LCD display (1-3kva) | ||||||
| 1KT | 1KT-XL | 2KT | 2KT-XL | 3KT | 3KT-XL | ||
| Capacity | VA/W | 1000VA/700W | 2000VA/1400W | 3000VA/2100W | |||
| Input | Low line transfer | 160VAC/140VAC/120VAC/110VAC 5VAC | |||||
| Low line comeback | 175VAC 5VAC | ||||||
| High line transfer | 300VAC 5VAC | ||||||
| High line comeback | 285VAC 5VAC | ||||||
| Frequency range | 50Hz: 46-54Hz; 60Hz: 56-64Hz | ||||||
| Phase | Single phase with ground | ||||||
| Power factor | 0.95 | ||||||
| Output | Voltage | 220/230/240VAC | |||||
| Voltage regulation | 2% | ||||||
| Frequency | Synchronization range (line mode); 50 or 60 (10. 2%) Hz (battery mode) | ||||||
| Current crest radio | 3:1 | ||||||
| Voltage distortion | 3% THD (linear load) | 4% THD (linear load) | |||||
| 4% THD (linear load) | 4% THD (linear load) | ||||||
| Waveform | Pure sine wave | ||||||
| Battery | Type and number | 12V/7AH 3 | Depending on the capacity of external batteries | 12V/7AH 8 | Depending on the capacity of external batteries | 12V/7AH 8 | Depending on the capacity of external batteries |
| Back up time (full load) | >5 minutes | >9 minutes | >5 minutes | ||||
| Recharge time | 5 hours to 90% | 5 hours to 90% | 5 hours to 90% | ||||
| Charging current | 1.0A | 8A | 1.0A | 8A | 1.0A | 8A | |
| Changing voltage | 41.1VDC 0.6V | 110VDC 0.4V | 110VDC 0.4V | ||||
| Transfer time | AC to DC | Zero | |||||
| Inverter to bypass | 2.5ms (typical) | ||||||
| Indicator | Status | Load level / battery level / battery mode / AC mode / bypass mode / fault | |||||
| Audible alarm | Overload | Sounding twice every second | |||||
| Low battery | Sounding every second | ||||||
| Fault | Continuously sounding | ||||||
| Battery mode | Sounding every 4 seconds | ||||||
| Physical | UPS case | 482.645087 (w.battery) | 482.645087 (w.battery) | ||||
| Dimensions DWH (mm) | 400145220 | 46192340 | |||||
| Net weight(Kg) | 14 | 7 | 34.5 | 15 | 35.5 | 16 | |
| Environment | Operating environment | 0-40, 20-90% relative humidity (non-condensing) | |||||
| Noise level | Less than 45dB@1 meter | Less than 50dB@1 meter | |||||
| Interface | Smart RS232 | Software support windows family, Linux, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX and MAC | |||||
| SNMP (option) | Power management from SNMP manager and web browse | ||||||
| USB option | Support windows family and MAC OS | ||||||

- HP9116C & HP9316C series 6-20kVA UPS HP9116C & HP9316C series 6-20kVA UPSApplications of HP9116C & HP9316C series 6-20kVA UPSHP9116C & HP9316C series 6-20kVA is quite suitabl

- HP9116CR & HP9316CR series 1-10kVA UPS HP9116CR & HP9316CR series 1-10kVA UPSApplication of HP9116CR & HP9316CR series Rack Mount Online UPSHP9116CR & HP9316CR series rack moun

- HP9330C series 20-80kVA UPS HP9330C series 20-80kVA UPSApplication of HP9330C series 20-80kVA UPSHP9330C series 20-80kVA UPS is particularly applicable to severs, data centers,

- GP series 6-30kVA UPS GP series 6-30kVA UPSOur GP series 6-30kVA UPS is composed of GP11 series UPS, GP911 series UPS, GP 31 series UPS, and GP931 series UPS. Among them,

- GP series 10-200kVA UPS GP series 10-200kVA UPSGP series 10-200kVA UPS products include GP33 series and GP933 series UPS. They are widely used in data management equipment a


United Kingdom


English
Español
Русский