GC112A Gas Chromatograph

GC112A Gas Chromatograph



GC112A Gas Chromatograph

Features

1. The gas chromatograph offers high accuracy oftemperature control (optimum: 0.05C), high reliability andanti-interference.
2. Control and operating parameters, including for detectors,can be set up by the keyboard. Settings include elf-diagnosis system,power-fail protection, file storage and load, and limited temperature. The gaschromatograph uses accurate display of setting and actual value of temperaturecontrol of each path, bridge current of TCD, sensitivity of FID, retention andanalysis time.
3. It offers four paths of independent controlsections, including column oven, sample injector, detector and thermalconductive pond.
4. It has 5-rampprogrammed temperature rising control and auto-drop of temperature of columnoven to a fast cooling.
5. Dual FID providedwith options of GC112 A-TCD, GC 112 A-FPD and GC112A-NPD, gas sampling valve,transformation oven, absorber and pyrolysis absorber are available forselection. Two detectors can be installed at the same time with highsensitivity. It takes a short time to be stabilized, it is easy to clean andinstall nozzle.
6. A packed column and capillary column (0.53 large diameter orsmall diameter) can be easily installed including a complete set of split samplingconnector and tailing connector to be installed free of charge. An optional 0.53mm large diametercapillary direct sampler is available for choice.
7. Analysis can be conducted in packed or capillary column with multiplesampling methods.
8. A packed column can finish on-column sampling, instantaneousvaporized sampling and gas sampling.
9. The gas chromatograph usescapillary column, which can support split sampling and 0.53mm large diameter capillarydirect sampling.
10. Construction of dual gas path, dual sampleinjector and dual packed column system can effectively avoid baselineundulation and drift in real time and facilitate programmed temperature risinganalysis. Accurate and scaled type gas path control valves will providerepeatability and stability of the gas chromatograph.
11. The gas chromatograph supports an auto ON/OFFtemperature control system, permanent data storage, file storage and call andover-temperature protection.
12. The large capacity column oven (300x280x270mm) can hold capillarycolumn and dual packed column. Built-in heating filament structure is in favorof quartz capillary analysis.
13. A complete set of accessories includingpurifier, pressure-reducing valve, gas path tube, wrench and tools, injectionneedle and connectors of all kinds are provided free of charge and are ready toconnect with the supply-air system prepared by users.

TechnicalSpecifications

TemperatureControl

Control range

7C - 400C above ambient. (increment of 1C)

Control objects

Column oven, detector, thermal conductive pond and sample injector

Programmed temperature rising

5 ramps

Rate of programmed temperature rising

0.1C -40C (increment of 0.1C)

Thermostatic time

0-655 min (increment of 1 min)


FID

Sensitivity (minimum testability)

M510-11 g/s (sample: C16)

Optimum testing result

M110-11 g/s

Noise

510-14 A

Drift

610-13 A/h

Linear range

106


TCD

Sensitivity

2000mV.ml/mg

Noise

20mV

Drift

30mV

Linear range

104


FPD

Sensitivity (minimum testability)

210-11 g (P)/s (sample P in the parathion methyl)

Optimum testing result: 3.810-12 g (P)/s.

Sensitivity (minimum testability)

110-10 g (S)/s (sample: S in the parathion methyl)

Optimum testing result: 2.710-11 g (S)/s

Linear range

103 (sample P parathion)

102 (sample S parathion)

Stability

30mV/h

Noise

10mV

Starting time

Not greater than 2 hours


NPD

Sensitivity (minimum testability)

Dt (N)5pg (N)/s

Optimum testing result: 0.5ppm

Sensitivity (minimum testability)

Dt(P) 0.5pg (P)/s

Optimum testing result: 0.2ppm

Drift

810-13 A/h

Noise

510-13 A

Linear range

103

Max application temperature

360C


Optional Accessories

1.TCD
2.FPD
3.NPD
4.CDP-4A data processor
5.N-2000 chromatogram workstation


Shipping Package

Dimension: 850x680x750mm
N. W.: 50kg
G. W.:65kg


INESA is an experienced gas chromatograph manufacturer in China. Apart from chromatograph, we also provideatomic absorption spectrophotometer, spectrophotometer, flame photometer, multi-parametermeter, meltingpoint apparatus, pH meter and more.

Feedback Form
Other Products
  • GC122 Gas Chromatograph GC122Gas ChromatographFeatures1. The GC122 gas chromatograph is newlydesigned, high performance HRGC.2. The double FID detectors in the basic typefea
  • FP640 Flame Photometer FP640Flame PhotometerFeatures1. This flame photometer is equipped with an LCD displayand LPG gas path system, so it is easy to operate and has stable
  • FP6410 Flame Photometer FP6410Flame PhotometerFeatures1. The flame photometer uses LCD display. Bythe application of a top grade embedded mono-chip computer circuit, it supp
  • WYA ABBE Refractometer WYA ABBE RefractometerFeatures1. Measurement of refractive index nD, average dispersion nF-nC oftransparent or translucent liquid and solid substance
  • G Series Spectrophotometer G Series SpectrophotometerModel: 721G/ 722G Visible Spectrophotometer 752GUV-VIS SpectrophotometerFeatures1. With holographic flashing grating, the G

United States | Argentina | Brazil | China | France | Germany | Japan | Korea | Russia | Spain | Switzerland | Thailand | UAE | United Kingdom | Vietnam | Poland | Italy | Morocco | Malaysia | Portugal | India | Canada

Copyright © 2008 - ETW International. All rights reserved.