- WYA-Z/WYA-ZT Automatic ABBE Digital Refractometer
- 723N Visible Spectrophotometer
- G Series Spectrophotometer
- WYA ABBE Refractometer
- FP6410 Flame Photometer
- FP640 Flame Photometer
- GC122 Gas Chromatograph
- GC112A Gas Chromatograph
- GC102AF/GC102AT Gas Chromatograph
- 4530 Atomic Absorption Spectrophotometer
- AA320N Atomic Absorption Spectrophotometer
- F96PRO Fluorescence Spectrophotometer
- F93 Fluorescence Spectrophotometer
- S410 NIR Spectrophotometer
- 765 UV-VIS Spectrophotometer
- 757 UV-VIS Spectrophotometer
- WGT-S Hazemeter
- X-4 Melting Point Apparatus With Microscope
- WRS-2/2A Micro Processor Melting Point Apparatus
- WRS-1B Digital Melting Point Apparatus
- WRR Visual Melting Point Apparatus
- SGW-1/SGW-2/SGW-3 Automatic Polarimeter
- WZZ-2S Automatic Polarimeter
- WZZ-3 Automatic Polarimeter
- WZZ-2B Automatic Polarimeter
- WXG-4 Disc Polarimeter
- WYA-2S ABBE Digital Refractometer
- WYA-2W ABBE Refractometer
- Temperature Sensor
- Dissolved Oxygen Sensor
- Ion Selective Sensors
- Metal Sensor
- Conductivity Sensor
- Reference Sensor
- pH Sensor
- COD-571/572 Chemical Oxygen Demand Meter
- ZDJ-5 Automatic Titrator
- ZDJ-4A Automatic Potential Titrator
- ZD-2 Automatic Potential Titrator
- DZS-708 Multi-Parameter Water Quality Meter
- DZS-706 Multi-Parameter Water Quality Meter
- DZB-718, DZB-712 Portable Multi-Parameter Meter
- PXB-286 Portable Ion Meter
- PXSJ-216 Ion Meter
- PXSJ-226 Ion Meter
- JPSJ-605 Benchtop Dissolved Oxygen Meter
- JPB-607A Portable Dissolved Oxygen Meter
- JPBJ-608 Portable Dissolved Oxygen Meter
- DDSJ-318 Conductivity Meter
- DDS-307A Conductivity Meter
- DDSJ-308A Conductivity Meter
- DDB-303A Portable Conductivity Meter
- DDBJ-350 Portable Conductivity Meter
- PHSJ-5 pH Meter
- PHSJ-3F pH Meter
- PHSJ-4A pH Meter
- PHS-3G Benchtop pH Meter
- PHS-3E pH Meter
- PHS-3C pH Meter
- PHB-4 Portable pH Meter
- PHBJ-260 Portable pH Meter
- WGZ-2000 Ratio Turbidimeter
- WGZ-200 Ratio Turbidimeter
- WSB-L White Meter
- WSF-J Spectroscopic Color Photometer
- WSC-S Colorimeter and Color Difference Meter
- WSL-2 Tintometer
- WGW Photoelectric Hazemeter
- WQS Vibrator
GC102AF/GC102AT Gas Chromatograph
GC102AF/GC102ATGas Chromatograph
Features
1. Allcontrol and application parameters of this gas chromatograph can be set upthrough the keyboard. Functions, such as self-diagnosis, switch-off protection,document storage and transaction, limit temperature setup thermal trip valvesetup, and FID auto-ignition are incorporated inside of the instrument.
2. The LCDdisplay can accurately present all temperature control setup values, actualvalues, TCD (GC102AT) working electricity supply, sensitivity of FID (GC102AF)magnifier, etc.
3. The gas chromatograph supports packed column i.e., on-columnsample injection. It is compatible with such devices as instantaneousvaporizing sample injection, gas sample injection with gas sample injectionvalves, and 0.53mm large diametercapillary column direct sampler.
4. The open-end computer system can apply RS-232 interface andN-2000 chromatogram workstation to achieve single path communication controland data processing.
5. The large capacity column oven (300280270mm) of the gaschromatograph is easy to install with packed column and large diametercapillary column.
Performance Indicators
TemperatureControl
1.Temperature control areas:column,sampler, detector
2.Temperature control range:ambient -399 (increment by 1)
3.Temperature control accuracy: less than 0.1 (measuredat 200)
FlameIonization Detector (GC102AF)
1.Detection limit: Mt110-10g/s (C16)
2.Drift: 210-12A/h
ThermalConductivity Detector (GC102AT)
1.Sensitivity:S1500mV.ml/mg(carrier gas: H2; sample: n-Hexadecane)
2.Baseline noise:20V
3.Baseline drift: 50V/h
OptionalAccessories
1.CDP-4A data processor
2.N-2000 chromatogram workstation
ShippingPackage
Dimension:950x670x770mm
G. W.:65kg
N. W.: 45kg
INESA is an experienced gas chromatograph manufacturer and supplier, based in China. We also provide fluorescencespectrophotometer, atomic absorption spectrophotometer, spectrophotometer,conductivity meter, refractometer, and more.

- GC112A Gas Chromatograph GC112A Gas ChromatographFeatures1. The gas chromatograph offers high accuracy oftemperature control (optimum: 0.05C), high reliability andanti-inter

- GC122 Gas Chromatograph GC122Gas ChromatographFeatures1. The GC122 gas chromatograph is newlydesigned, high performance HRGC.2. The double FID detectors in the basic typefea

- FP640 Flame Photometer FP640Flame PhotometerFeatures1. This flame photometer is equipped with an LCD displayand LPG gas path system, so it is easy to operate and has stable

- FP6410 Flame Photometer FP6410Flame PhotometerFeatures1. The flame photometer uses LCD display. Bythe application of a top grade embedded mono-chip computer circuit, it supp

- WYA ABBE Refractometer WYA ABBE RefractometerFeatures1. Measurement of refractive index nD, average dispersion nF-nC oftransparent or translucent liquid and solid substance


United Kingdom


English
Español
Português