- Inverter
- Gallery
- Principle,Wiring
- Technical Parameters
- Gallery
- Physical Features
- Physical Features
- Technical Parameters
- Principle,Wiring
- Applications
- CATV UPS, EX-0614
- DC Axial UPS Cooling Fan
- UPS Cooling Fan
- 10-20kVA UPS
- 20kVA UPS and UPS higher than 20kVA
- 6-10kVA UPS
- 1-3kVA UPS
- 500VA-1200VA UPS
- HW9110E High Performance Integrated Outdoor Online UPS, 1kVA-10kVA
- GM Series 6 - 20kVA
- G Series 1 - 3kVA
- GM Series 6 - 20kVA
- G Series 1 - 3kVA
- LG Series 500-1200VA
- ST Series 1 - 3kVA
- HP9330C Series 10 - 80kVA
- GP Series 10 - 200kVA
- GP Series 6 - 30kVA
- HP9116C & HP9316C Series 6-20kVA UPS
- HP9116C Series 1 - 3kVA
- B Series 500-1200VA
- ST Series 1 - 3kVA
- HP9117C series1 - 3kVA
- GP series 10-200kVA UPS
- GP series 6-30kVA UPS
- HP9330C Series 10 - 80kVA
- HP9116CR & HP9316CR series 1-10kVA UPS
- HP9116C & HP9316C Series 6-20kVA UPS
- HP9116C Series 1 - 3kVA
- G / GM Series 6 - 20kVA
- G / GM Series 1 - 3kVA
- ST Series 1 - 3kVA
- GP series 10-200kVA UPS
- GP series 6-30kVA UPS
- HP9330C series 20-80kVA UPS
- HP9116CR & HP9316CR series 1-10kVA UPS
- HP9116C & HP9316C series 6-20kVA UPS
- HP9116C Series 1-3kVA UPS
- G-GM series 6-20kVA UPS
- G-GM Series 1-3kVA UPS
- Difference Between EPS and UPS
- Passive Power Filter
- Active Power Filter (APF)
- Power Filter
- UPS Cooling Fan
- UPS Battery Charger
- UPS SNMP Card
- Inverter UPS Accessories
- Lighting Power EPS (Emergency Power Supply)
- Lighting EPS (Emergency Power Supply)
- EPS (Emergency Power Supply)
- UPS System
- LED UPS
- LCD UPS
- Low Frequency Online UPS
- High Frequency Online UPS
- ST Series 1-3kVA UPS
- HP9117C Series 1-3kVA UPS
- Online UPS
- UPS (Uninterruptible Power Supply)
- Off Line UPS
G-GM series 6-20kVA UPS
Applications of G-GM series 6-20kVA UPS
G - GM series 6-20kVA is widely applied to servers, data centers, critical network devices, sensitive electronic equipment, telecommunications, etc.
Features of G-GM series 6-20kVA UPS
1. Designed with on-line double conversion technology, and employs advanced microprocessor control.
2. Wide input voltage range.
3. Zero transfer time
4. Protection devices against all types of power problems.
5. Self test while starting UPS.
6. Site wiring fault warning.
7. On-battery power-on function.
8. Smart RS232 communication interface.
9. Intelligent slot is available.
10. Sealed, lead-acid, and maintenance free battery.
11. N+X parallel redundancy and capacity expansion.
Technical Specification
| Product series | 6 - 10kVA (1 PH / 1 PH) | 10 - 20kVA (3PH / 1PH) | ||||||
| Model number | G6K | G10K | G6KS | G10KS | 3G10KS | 3G15KS | 3G20KS | |
| GM6K | GM10K | GM6KS | GM10KS | 3GM10KS | 3GM15KS | 3GM20KS | ||
| Rated power | Volt-amps/Watts | 6kVA/ 4.2KW | 10 kVA /8KW | 6 kVA /4.2KW | 10 kVA /7KW | 10V kVA /7KW | 15 kVA /10.5KW | 20 kVA /14KW |
| Input | Nominal voltage | 220VAC or 230VAC or 240VAC | 380VAC | |||||
| Voltage range | 176-276VAC | 304-478VAC | ||||||
| Frequency range | 50Hz: 46-54Hz, 60Hz: 56-64Hz | |||||||
| Power factor | 0.98 | 0.95 | ||||||
| Phase | Single phase | Three phase (4 wires ground) | ||||||
| Connection | Hardwired | |||||||
| Output | Voltage | 220VAC or 230VAC or 240VAC (1 2% ) | ||||||
| Frequency | Synchronized 46-54Hz(line mode), 50/60Hz (1 0.1% ) Hz (battery mode) | |||||||
| Power factor | 0.7 or 0.8 | |||||||
| Wave form | Pure sine wave | |||||||
| Phase | single phase | |||||||
| Voltage distortion | 2% THD (linear load), 6% THD (non-linear load) | |||||||
| Overload capability | 105%~130% for 10 min., more than 130% for 1 second | |||||||
| Current crest ratio | 3:1 max | |||||||
| Connection | Hardwired | |||||||
| Battery | Type | Valve regulated, sealed, lead-acid | External battery bank | |||||
| Nominal DC voltage | 240VDC | |||||||
| Backup time (full load) | 7 min | 5 min | Depends on the external battery capacity | |||||
| Recharge time | 7 hours to 90% | 8 hours to 90% | Depends on the external battery capacity | |||||
| Charge current (Max.) | 2A | 4.2A | ||||||
| Charge voltage | 274Vdc 1V | |||||||
| Transfer time | AC to DC | 0 ms | ||||||
| Inverter to bypass | 2.5 ms (typical) | |||||||
| Indicators | LED display | Load level / battery level, battery, utility power, inverter, bypass, overload, fault | ||||||
| Audible alarm | Bypass | Alarm beeps every two seconds | ||||||
| Battery discharge | Alarm beeps every four seconds. Alarm beeps every one second if battery low. | |||||||
| Overload | Alarm beeps twice for every one second | |||||||
| Fault | Alarm beeps continuously. | |||||||
| Maintenance bypass switch | Yes | |||||||
| Communications interface | DB-9 port | RS-232 serial interface | ||||||
| Intelligent slot | Options: SNMP card, AS400 card or Win power CMC / (USB port) | |||||||
| Parallel port | Availability of up to three units in parallel for power redundancy and load sharing | |||||||
| Environment | Operating temperature | 0 ~ 40 | ||||||
| Operating humidity | 20 ~ 90% non-condensing | |||||||
| Noise level | Less than 55dB@1 meter | Less than 60dB@1 meter | ||||||
| Physical feature | Weight net (Kg) | 84 | 93 | 35 | 38 | 39 | 55 | |
| Body size (WDH) (mm) | 260570717 | |||||||
SH Power Co.,Ltd. is an ISO9001: 2000 certified LED UPS manufacturer located in China. Over ten years manufacturing experience in this industry has enabled us to offer high quality UPS products to our customers. These products could be off line UPS, online UPS, UPS ANMP card, LCD UPS, LED UPS, and more.
Our CE certified UPS products have advantages of high working efficiency, superior quality and economical prices, and are widely exported to the United States, Italy, Austria, Germany, and other countries.
For further inquiries and purchase of LED UPS or any of our UPS products, please do contact us. We are competent that we are your one stop shopping centre for all your UPS needs.

- HP9116C Series 1-3kVA UPS HP9116C Series 1-3kVA UPSApplications of HP9116C Series 1-3kVA UPSHP9116C Series 1-3kVA can be widely suitable for servers, data centers, critical ne

- HP9116C & HP9316C series 6-20kVA UPS HP9116C & HP9316C series 6-20kVA UPSApplications of HP9116C & HP9316C series 6-20kVA UPSHP9116C & HP9316C series 6-20kVA is quite suitabl

- HP9116CR & HP9316CR series 1-10kVA UPS HP9116CR & HP9316CR series 1-10kVA UPSApplication of HP9116CR & HP9316CR series Rack Mount Online UPSHP9116CR & HP9316CR series rack moun

- HP9330C series 20-80kVA UPS HP9330C series 20-80kVA UPSApplication of HP9330C series 20-80kVA UPSHP9330C series 20-80kVA UPS is particularly applicable to severs, data centers,

- GP series 6-30kVA UPS GP series 6-30kVA UPSOur GP series 6-30kVA UPS is composed of GP11 series UPS, GP911 series UPS, GP 31 series UPS, and GP931 series UPS. Among them,


United Kingdom


English
Español
Русский