- Inverter
- Gallery
- Principle,Wiring
- Technical Parameters
- Gallery
- Physical Features
- Physical Features
- Technical Parameters
- Principle,Wiring
- Applications
- CATV UPS, EX-0614
- DC Axial UPS Cooling Fan
- UPS Cooling Fan
- 10-20kVA UPS
- 20kVA UPS and UPS higher than 20kVA
- 6-10kVA UPS
- 1-3kVA UPS
- 500VA-1200VA UPS
- HW9110E High Performance Integrated Outdoor Online UPS, 1kVA-10kVA
- GM Series 6 - 20kVA
- G Series 1 - 3kVA
- GM Series 6 - 20kVA
- G Series 1 - 3kVA
- LG Series 500-1200VA
- ST Series 1 - 3kVA
- HP9330C Series 10 - 80kVA
- GP Series 10 - 200kVA
- GP Series 6 - 30kVA
- HP9116C & HP9316C Series 6-20kVA UPS
- HP9116C Series 1 - 3kVA
- B Series 500-1200VA
- ST Series 1 - 3kVA
- HP9117C series1 - 3kVA
- GP series 10-200kVA UPS
- GP series 6-30kVA UPS
- HP9330C Series 10 - 80kVA
- HP9116CR & HP9316CR series 1-10kVA UPS
- HP9116C & HP9316C Series 6-20kVA UPS
- HP9116C Series 1 - 3kVA
- G / GM Series 6 - 20kVA
- G / GM Series 1 - 3kVA
- ST Series 1 - 3kVA
- GP series 10-200kVA UPS
- GP series 6-30kVA UPS
- HP9330C series 20-80kVA UPS
- HP9116CR & HP9316CR series 1-10kVA UPS
- HP9116C & HP9316C series 6-20kVA UPS
- HP9116C Series 1-3kVA UPS
- G-GM series 6-20kVA UPS
- G-GM Series 1-3kVA UPS
- Difference Between EPS and UPS
- Passive Power Filter
- Active Power Filter (APF)
- Power Filter
- UPS Cooling Fan
- UPS Battery Charger
- UPS SNMP Card
- Inverter UPS Accessories
- Lighting Power EPS (Emergency Power Supply)
- Lighting EPS (Emergency Power Supply)
- EPS (Emergency Power Supply)
- UPS System
- LED UPS
- LCD UPS
- Low Frequency Online UPS
- High Frequency Online UPS
- ST Series 1-3kVA UPS
- HP9117C Series 1-3kVA UPS
- Online UPS
- UPS (Uninterruptible Power Supply)
- Off Line UPS
G-GM Series 1-3kVA UPS
Application of G-GM Series 1-3kVA UPS
G-GM series 1-3kVA can be applicable to servers, data centers, critical network devices, sensitive electronic equipment, telecommunications, etc.
Features of G-GM Series 1-3kVA UPS
1. Designed with online double conversion technology, and employs advanced microprocessor control.
2. Wide input voltage range.
3. Zero transfer time.
4. Protection against all types of power problems.
5. Self test while starting the UPS.
6. Site wiring fault warning.
7. On-battery power-on function.
8. Smart RS232 communication interface.
9. Intelligent slot is available.
10. Sealed, lead-acid, and maintenance free battery.
Technical Specifications
| Model | G1K | G2K | G3K | G1KS | G2KS | G3KS | |
| GM1K | GM2K | GM3K | GM1KS | GM2KS | GM3KS | ||
| Capacity | VA/W | 1kVA/ 0.7KW | 2kVA/ 1.4KW | 3kVA/ 2.1KW | 1kVA/ 0.7KW | 2kVA/ 1.4KW | 3kVA/ 2.1KW |
| Input | Nominal voltage | 110/115/120 VAC or 220/230/240 VAC | |||||
| Voltage range | 180-300VAC | ||||||
| Frequency range | 50Hz, 46-54Hz, 60Hz, 56-64Hz. | ||||||
| Phase | Single phase | ||||||
| Power factor | >0.97 | ||||||
| Connection | IEC320 -10A inlet | IEC320 -10A inlet | IEC320 -16A inlet | IEC320 -10A inlet | IEC320 -10A inlet | IEC320 -16A inlet | |
| Output | Voltage | 110/115/120 (12%) VAC, 220/230/240(12%)VAC | |||||
| Frequency | Synchronization range (line mode), 50 or 60Hz(10.2%) (Battery mode) | ||||||
| Phase | Single phase | ||||||
| Wave form | Sine wave | ||||||
| Power factor | 0.7 or 0.8 optional | ||||||
| Voltage distortion | 3% | 4% | 4% | 3% | 4% | 4% | |
| Overload capability | 110%-150% for 30 sec., 150% for 200 ms | ||||||
| Current crest radio | 3: 1 | ||||||
| Connections | IEC320*4 | IEC320*6 | IEC320*3 terminal block | IEC320*4 | IEC320*6 | IEC320*3 terminal block | |
| Battery and charge | Type | Sealed, maintenance free, and lead-acid | |||||
| Nominal DC to voltage | 36VDC | 96VDC | 96VDC | ||||
| Quantity | 3 pieces | 8 pieces | 8 pieces | Depends on the requested back-up time | |||
| Back-up time(full load) | 5 min | 9 min | 5min | Depends on the capacity of the external battery bank | |||
| Recharge time | 5 hrs to 90% of capacity | Depends on the capacity of the external battery bank | |||||
| Automatic transfer | On overload and UPS failure | ||||||
| Before UPS power-on | Default \'ON\' user adjustable to \'YES\' | ||||||
| Voltage range | 40-132VAC (default), user can adjust the voltage within 40-143VAC; 80-264VAC (default), user can adjust the voltage within 80-286VAC. | ||||||
| Transfer time | AC to DC zero | Inverter to bypass 4 ms (typical) | |||||
| Indicators | UG/LED display | Load level / battery / lever, battery, utility power, inverter, bypass, overload, fault | |||||
| UX/LCD display | UPS status, I/P and O/P voltage and frequency, battery voltage, battery capacity, loading, temperature, history record | ||||||
| Audible alarm | Bypass, on battery mode, battery low, overload, fault | ||||||
| Acoustic noise | At 1 meter distance | <45 dB | <50 dB | <50 dB | <45 dB | <50 dB | <50 dB |
| Communications | DB-9 port | PS-232 serial interface | |||||
| Intelligent slot | Options: SNMP card, AS400 card or Win power CMC / (USB port) | ||||||
| Environment | Operating temperature | 0-40 | |||||
| Operating humidity | 20-90% non-condensing | ||||||
| Weight | Net(Kg) | 13 | 31.5 | 32 | 7 | 13.5 | 14 |
| Dimensions (package) | W D H (mm) | 240495 335 | 335590 480 | 355590 480 | 240495 335 | 335590 480 | 335590 480 |
As a primary UPS product manufacturer in China, SH Power Co.,Ltd. is dedicated to produce high quality off line UPS, high frequency online UPS, low frequency online UPS, and more. Those products employ advanced digital control technology, and have strong extended function. Currently, our products are CE certified and exported to the United States, Russia, Austria, Brazil, and other countries as a result of high quality and economical prices.
Please do contact SH Power Co.,Ltd., should you require further information on our products or for orders via email or phone.

- G-GM series 6-20kVA UPS G-GM series 6-20kVA UPSApplications of G-GM series 6-20kVA UPSG - GM series 6-20kVA is widely applied to servers, data centers, critical network devi

- HP9116C Series 1-3kVA UPS HP9116C Series 1-3kVA UPSApplications of HP9116C Series 1-3kVA UPSHP9116C Series 1-3kVA can be widely suitable for servers, data centers, critical ne

- HP9116C & HP9316C series 6-20kVA UPS HP9116C & HP9316C series 6-20kVA UPSApplications of HP9116C & HP9316C series 6-20kVA UPSHP9116C & HP9316C series 6-20kVA is quite suitabl

- HP9116CR & HP9316CR series 1-10kVA UPS HP9116CR & HP9316CR series 1-10kVA UPSApplication of HP9116CR & HP9316CR series Rack Mount Online UPSHP9116CR & HP9316CR series rack moun

- HP9330C series 20-80kVA UPS HP9330C series 20-80kVA UPSApplication of HP9330C series 20-80kVA UPSHP9330C series 20-80kVA UPS is particularly applicable to severs, data centers,


United Kingdom


English
Español
Русский