- 3.05mm Galvanized Steel Wire
- 1.6mm Galvanized Steel Wire
- 2.64mm Galvanized Steel Wire
- 1*19 Galvanized Stranded Wire
- 1*7 Galvanized Stranded Wire
- BS4565-1990
- ASTM A475
- EN 50189
- 11.11mm Prestressed Concrete Strand Wire, PC Strand
- ASTM B498
- ASTMB498B 498M-2002
- 4.7mm Galvanized Steel Wire
- 17.80mm Prestressed Concrete Strand Wire, PC Strand
- 2.24mm Galvanized Steel Wire
- 12.70mm Prestressed Concrete Strand Wire, PC Strand
- 2.0mm Galvanized Steel Wire
- 15.24mm Prestressed Concrete Strand Wire, PC Strand
EN 50189
EN 50189 Standard
| Table 1. Initial Settings for Determining Stress 1% Extension | |||
| Nominal Wire Diameter, mm | Initial Stress, N/mm2 | Initial setting of extensometer for a gauge length of 250mm2 | |
| 1.24 | 2.25 | 100 | 0.125 |
| 2.25 | 3 | 200 | 0.25 |
| 3 | 4.75 | 300 | 0.375 |
| 4.75 | 5.5 | 400 | 0.5 |
| For other gauge lengths, multiply the initial setting by the gauge length in mm divided by 250. | |||
| Table 2. Zinc Coating Requirements | |||||||||||
| Nominal Wire Diameter, mm | Class A | Class B | Class C | Class D | Class E | ||||||
| Over | Up to and incl. | Min. mass of Zn g/m2 | Min. no. of one minute dips | Min. mass of Zn g/m2 | Min. no. of one minute dips | Min. mass of Zn g/m2 | Min. no. of one minute dips | Min. mass of Zn g/m2 | Min. no. of one minute dips | Min. mass of Zn g/m2 | Min. no. of one minute dips |
| 1.24 | 1.5 | 185 | 2 | 370 | 3.5 | 150 | 1 | 365 | 3 | 185 | 2 |
| 1.5 | 1.75 | 200 | 2 | 400 | 3.5 | 160 | 1.5 | 460 | 3.5 | 200 | 2 |
| 1.75 | 2 | 215 | 2.5 | 430 | 4 | 175 | 2 | 550 | 4 | 215 | 2.5 |
| 2 | 2.25 | 215 | 2.5 | 430 | 4 | 175 | 2 | 550 | 4 | 250 | 3.5 |
| 2.25 | 2.75 | 230 | 3 | 460 | 4 | 190 | 2.5 | 640 | 5 | 250 | 3.5 |
| 2.75 | 3 | 230 | 3 | 460 | 4 | 190 | 2.5 | 640 | 5 | 250 | 3.5 |
| 3 | 3.5 | 245 | 3.5 | 490 | 4 | 205 | 3 | 730 | 6 | 250 | 3.5 |
| 3.5 | 4.25 | 260 | 3.5 | 520 | 4 | 260 | 3.5 | 730 | 6 | 260 | 3.5 |
| 4.25 | 4.75 | 275 | 4 | 550 | 4 | 275 | 4 | 775 | 6 | 275 | 4 |
| 4.75 | 5 | 200 | 4 | 580 | 5 | 290 | 4 | 825 | 6 | 290 | 4 |
| 5 | 5.25 | 290 | 4 | 580 | 5 | 290 | 4 | 825 | 6 | 290 | 4 |
| 5.25 | 5.5 | 290 | 4 | 580 | 5 | 290 | 4 | 825 | 6 | 290 | 4 |
| Table 3. Mechanical Properties of ST1A Wires | |||||||
| Nominal wire diameter mm | Diameter tolerance | Stress at 1% extension, MPa | Tensile strength, MPa | Elongation on 250mm | Mandrel diameter for wrapping test | No. of torsion twists | |
| Over | Up to and incl. | mm | N/MM2 | N/MM2 | % | ||
| Min. | Min. | Min. | xd | Min. | |||
| 1.24 | 1.5 | 0.03 | 1170 | 1400 | 3 | 1 | 18 |
| 1.5 | 1.75 | 0.03 | 1170 | 1400 | 3 | 1 | 18 |
| 1.75 | 2.25 | 0.03 | 1170 | 1400 | 3 | 1 | 18 |
| 2.25 | 2.75 | 0.04 | 1140 | 1350 | 3 | 1 | 16 |
| 2.75 | 3 | 0.05 | 1140 | 1350 | 3.5 | 1 | 16 |
| 3 | 3.5 | 0.05 | 1100 | 1300 | 3.5 | 1 | 14 |
| 3.5 | 4.25 | 0.06 | 1100 | 1300 | 4 | 1 | 12 |
| 4.25 | 4.75 | 0.06 | 1100 | 1300 | 4 | 1 | 12 |
| 4.75 | 5.5 | 0.07 | 1100 | 1300 | 4 | 1 | 12 |
| Table 4. Mechanical properties of ST2B Wires | ||||||
| Nominal wire diameter mm | Diameter tolerance | Stress at 1% extension, MPa | Tensile strength, MPa | Elongation on 250mm | Mandrel diameter for wrapping test | |
| Over | Up to and incl. | mm | N/MM2 | N/MM2 | ||
| 1.24 | 1.5 | 0.05 | 1100 | 1300 | 4 | 1 |
| 1.5 | 1.75 | 0.05 | 1100 | 1300 | 4 | 1 |
| 1.75 | 2.25 | 0.05 | 1100 | 1300 | 4 | 1 |
| 2.25 | 2.75 | 0.06 | 1070 | 1250 | 4 | 1 |
| 2.75 | 3 | 0.06 | 1070 | 1250 | 4 | 1 |
| 3 | 3.5 | 0.07 | 1000 | 1200 | 4 | 1 |
| 3.5 | 4.25 | 0.09 | 1000 | 1200 | 4 | 1 |
| 4.25 | 4.75 | 0.10 | 1000 | 1200 | 4 | 1 |
| 4.75 | 5.5 | 0.11 | 1000 | 1200 | 4 | 1 |
| Table 5. Mechanical Properties of ST3D Wires | |||||||
| Nominal wire diameter mm | Diameter tolerance | Stress at 1% extension, MPa | Tensile strength, MPa | Elongation on 250mm | Mandrel diameter for wrapping test | No. of torsion twists | |
| Over | Up to and incl. | mm | N/MM2 | N/MM2 | |||
| 1.24 | 1.5 | 0.05 | 1210 | 1500 | 4 | 2 | 16 |
| 1.5 | 1.75 | 0.07 | 1210 | 1500 | 4 | 2 | 16 |
| 1.75 | 2.25 | 0.08 | 1210 | 1500 | 4 | 2 | 16 |
| 2.25 | 2.75 | 0.10 | 1210 | 15800 | 4 | 3 | 16 |
| 2.75 | 3 | 0.12 | 1210 | 1500 | 4 | 3 | 16 |
| 3 | 3.5 | 0.13 | 1100 | 1400 | 4 | 3 | 16 |
| 3.5 | 4.25 | 0.13 | 1100 | 1400 | 4 | 3 | 14 |
| 4.25 | 4.75 | 0.13 | 1100 | 1400 | 4 | 3 | 14 |
| 4.75 | 5.5 | 0.13 | 1100 | 1400 | 4 | 3 | 14 |
| Table 6. Mechanical Properties of ST4A Wires | |||||||
| Nominal wire diameter mm | Diameter tolerance | Stress at 1% extension, MPa | Tensile strength, MPa | Elongation on 250mm | Mandrel diameter for wrapping test | No. of torsion twists | |
| over | Up to and incl. | mm | N/MM2 | N/MM2 | |||
| 1.24 | 1.5 | 0.03 | 1275 | 1670 | 3.5 | 2 | 12 |
| 1.5 | 1.75 | 0.03 | 1275 | 1670 | 3.5 | 2 | 12 |
| 1.75 | 2.25 | 0.03 | 1275 | 1670 | 3.5 | 2 | 12 |
| 2.25 | 2.75 | 0.04 | 1275 | 1670 | 4 | 3 | 12 |
| 2.75 | 3 | 0.05 | 1275 | 1670 | 4 | 3 | 12 |
| 3 | 3.5 | 0.05 | 1225 | 1620 | 4 | 3 | 12 |
| 3.5 | 4.25 | 0.06 | 1225 | 1620 | 4 | 3 | 12 |
| 4.25 | 4.75 | 0.06 | 1225 | 1620 | 4 | 3 | 12 |
| 4.75 | 5.5 | 0.07 | 1225 | 1620 | 4 | 3 | 12 |
| Table 7. Mechanical Properties of ST5E Wires | ||||||
| Nominal wire diameter mm | Diameter tolerance | Stress at 1% extension, MPa | Tensile strength, MPa | Elongation on 250mm | Mandrel diameter for wrapping test | |
| over | Up to and incl. | mm | N/MM2 | N/MM2 | ||
| 1.24 | 1.75 | 0.03 | 1420 | 1620 | 3.5 | 4 |
| 1.75 | 2.3 | 0.04 | 1420 | 1620 | 3.5 | 4 |
| 2.3 | 2.55 | 0.04 | 1370 | 1620 | 4 | 4 |
| 2.55 | 2.75 | 0.04 | 1370 | 1670 | 4 | 4 |
| 2.75 | 3.5 | 0.05 | 1370 | 1670 | 4 | 4 |
| 3.5 | 4.75 | 0.06 | 1370 | 1670 | 4 | 4 |
| 4.75 | 5.5 | 0.07 | 1370 | 1670 | 4 | 4 |
| Table 8. Mechanical Properties of ST6C Wires | ||||||||
| Nominal wire diameter mm | Diameter tolerance | Stress at 1% extension, MPa | Tensile Strength | Elongation on 250mm | Mandrel diameter for wrapping test | No. of torsion twists | ||
| Min | Max | |||||||
| over | Up to and incl. | mm | N/MM2 | N/MM2 | N/MM2 | |||
| 1.24 | 1.5 | 0.03 | 1450 | 1700 | 1800 | 2 | 4 | 14 |
| 1.5 | 1.75 | 0.03 | 1450 | 1700 | 1800 | 2 | 4 | 14 |
| 1.75 | 2.25 | 0.04 | 1450 | 1700 | 1800 | 2 | 4 | 14 |
| 2.25 | 2.75 | 0.04 | 1410 | 1650 | 1750 | 2 | 4 | 14 |
| 2.75 | 3.0 | 0.05 | 1410 | 1650 | 1750 | 2.5 | 4 | 12 |
| 3.0 | 3.5 | 0.05 | 1380 | 1600 | 1700 | 2.5 | 4 | 12 |
| 3.5 | 4.25 | 0.06 | 1340 | 1600 | 1700 | 2.5 | 5 | 10 |
| 4.25 | 4.75 | 0.06 | 1340 | 1600 | 1700 | 2.5 | 5 | 10 |
| 4.75 | 5.5 | 0.07 | 1340 | 1600 | 1700 | 2.5 | 5 | 10 |

- ASTM A475 ASTM A475 Standard Dia. of strand, in(mm) Minimum Breaking Strength of Strand,1bf(kN) Weight of Zine Coating, g/m2 High Strength

- BS4565-1990 BS4565-1990 Standard Table 1. Initial Settings for Determining Stress 1% Extension Nominal Diameter of Galvanized Steel Wire Initi

- 1*7 Galvanized Stranded Wire 1*7 Galvanized Stranded Wire 1*7 Galvanized StrandedWire DescriptionOur galvanized stranded wires provide acombination of superior prope

- 1*19 Galvanized Stranded Wire 1*19 Galvanized Stranded Wire 1*19Galvanized Stranded WireConstruction &Diameter of 19 Strand Steel Wire Rope is 1*19/8.0-16.0mm.Featu

- 2.64mm Galvanized Steel Wire 2.64mm Galvanized Steel Wire DescriptionDingtai, a China-basedantirust steel wire supplier, offers a wide range of galvanized steel wires forboth ind


United Kingdom


English
Español
العرب