- 200A, 15kV Fused Loadbreak Elbow Connector
- Metal Stamping Parts
- 600A,35kV Integral Deadbreak Bushing
- 630A 12-24kV Integral Deadbreak Bushing with Flange
- 630A, 24kV Two Side Bushing
- ELE 12-24kV SF6 Ring Main Unit
- Earth and Short Circuit Fault Indicator
- Cable Short Circuit Fault Indicator
- Overhead Short Circuit Fault Indicator
- Fault Indicator
- 630A, 24kV Integral Deadbreak Bushing with Test Point
- SMC LV and HV Cable Distribution Cabinet
- Scrap Metal Baler Push Out Type
- Scrap Metal Baler Turnout Type
- Hollow Shock Absorber Piston Rod
- Terms of trade
- Shock Absorber Piston Rod
- Automobile Piston Rod
- Pneumatic Cylinder Rod, Cylinder Piston Rod
- 200A, 15kV Loadbreak Junction
- 630A, 24kV Insulated Protective Cap
- 250A, 24kV Insulated Protective Cap
- 600A, 15kV-35KV Insulated Protective Cap
- 200A, 15kV-35KV Insulated Protective Cap
- 200A, 15kV Loadbreak Portable Feedthru
- 200A, 15kV-35kV Insulated Standoff Bushing
- 200A, 15kV Rotatable Feedthru Insert
- 200A, 15-35kV Loadbreak Bushing Insert
- 250A, 24kV Deadbreak Bushing Insert
- 630A, 36kV Straight Connector
- 250A, 24kV Deadbreak Straight Connector with Cable Adapter and Jacket Seal
- 630A, 24kV Shielded Fore-Connector with Silicone Rubber
- 630A, 24kV Shielded Sub-Connector with Silicone Rubber
- 630A, 24kV-36kV Shielded Fore-Connector with Cable Adapter and Jacket Seal
- 630A, 24kV -36kV Shielded Sub-Connector with Cable Adapter and Jacket Seal
- 600A, 15-35kV Deadbreak Tee Connector
- 250A, 24kV Deadbreak Elbow Connector
- 200A, 15kV Grounding Elbow Connector
- 200A, 15-35kV Loadbreak Elbow Connector
- Separable Connector, Cable Connector
ELE 12-24kV SF6 Ring Main Unit
ELE 12-24kV SF6 RingMain Unit
Productfeature
Fully Insulated and Sealed Design
ELEseries switchgear contains a stainless steel tank filledwith SF6 gas, in which the primary live parts, the busbar and switch contacts are kept. The bushing interfacedesign is via standardized outer cone bushings to EN 50180/50181 (DIN 47636),which connect the cables via insulated and shielded separable connectors. The ingress protection rating of the gas tank canreach IP67. Outside part of gas tank can resistshort-time flood and dewdrop because of special design and surface process.
Standard Modularize Design
Basicunits include loadbreak switchunit (module C andN), loadbreak switch-fusecombination unit(module T), circuitbreaker unit (moduleV and V0), busbar switchunit (module S, D, VS, VD),metering unit(module M), busbar PT unit(module P), cablefeeder unit (moduleB), Z unit, ZDunit etc…Different modules can be combined andassembled in one SF6 insulated tank.
Flexible Extensible Design
ELE-Fseries are un-extensible switchgear, combined by basic units in one tank. ELE-Eseries flexible extensible units provide the user with diversified solutions,for which different tank was connected electrically on the top by busbar connector.
Unique and Economic Solution for Power Cable Connection
ELEseries switch configuration scheme have outlet bushings on both sides. Itprovides unique and economic solution for multi-cable branching andsectionalizing system.
Service Conditions
1. Altitude: Notmore than 4000m.(If altitude exceed 1000m, please point out, so that pressure can beadjusted when manufacture.)
2. Ambienttemperature: +50℃ for maximum, -40℃ for minimum, no more than 35℃ for average ambient temperature within 24hrs.
3. Ambienthumidity: no more than 95% for average relative humidity within 24hrs, no more than 90% for averagerelative humidity within one moneh.
4.Installation condition: No explosive or corrosive gas in the ambient air; noshock and vibration at the field; pollution grade is not more than III gradedefined in standard GB/T 5582.
5. Accelerationof the earthquake: less than 0.3gin the horizontal direction, lessthan 0.15g in the verticaldirection.
Standards
GB3804-2004, 3.6Kv-40.5 kVHigh-voltage switches(IEC 60265-1:1998,MOD)
GB1984-2003 High-voltage circuit breaker
GB16926-1997, High-voltagealternating current switch-fuse combinations (equivalent to IEC 60420:1990)
GB1985-2004, High-voltagealternating current disconnectors and earthingswitches(IEC 62271-102:2002,MOD)
GB3906-2006, 3.6Kv-40.5 kV High-voltageswitchgear and control gear(IEC62271-200:2003,MOD)
Q/GDW-10-324-2008Technical specifications for 20KV medium voltage ring main switchgears
GB/T11022-1999, Commonspecifications for high-voltage switchgear and control gearstandards (equivalent to IEC 60694:1996)
GB/T11023-1989, Test guide of SF6gas tightness for high-voltage switchgear
GB4208-1993, Degrees ofprotection provided by enclosures (IP code) (equivalent to IEC 60529:1989)
GB/T5582-1993, External insulation pollution classes of high-voltage electric powerequipments (IEC 507:1991 REF)
DL/T404-1997 Technical specifications for ordering indoor A.C. metal-enclosedswitchgear (equivalent to IEC 60298:1981)
GB/T14436 General principles of industrial product guarantee documents
JB/T8754-1998Organization of the types of high-voltage switchgear and control gear
GB/T6388 Transport package shipping mark
GB/T13384, General specifications for packaging of mechanical and electrical products
Application
Because SF6-insulated ring main unit ismaintenance-free, compact and independent of altitude, dewdrop, contaminant,small animals and chemical substance etc., it is widely used at manypower-supplied systems, which has high level of reliability such as commercialcenter, industrial zone, airports and speedways. SF6-insulated ringmain unit can not only be used indoors or outdoor separately, but alsointegrated with high voltage/low-voltage prefabricatedsubstation. ELE series SF6-insulated ring mainunit wholly brought in advanced facilities and manufacture technology, and allour products are localized made in China. The competitive costs andprompt lead-time won good reputation in the market worldwide.
Technicalspecification
| Item | Unit | C Unit | F Unit | V Unit |
| Rated voltage | kV | 12/24 | 12/24 | 12/24 |
| Rated frequency | Hz | 50 | 50 | 50 |
| Rated current | A | 630 | Depending on the current rating of the fuse. | 630 |
| Rated insulated level 1min. power frequency withstand voltage (To earth & between phase) 1min. power frequency withstand voltage(Across the isolating distance) 1min. power frequency withstand voltage(Auxiliary and control circuits) Rated lightning impulse withstand voltage(To earth & between phases) Rated lightning impulse withstand voltage(Across the isolating distance) | kV | 42/65 48/79 2/2 75/125 85/145 | 42/65 48/79 2/2 75/125 85/145 | 42/65 48/79 2/2 75/125 85/145 |
|
|
|
|
|
|
| Rated Short-time withstand current(r.m.s) | kA | 25/3s/20/3s | - | 25/2S/20/4s |
| Rated peak withstand current | kA | 63/50 | - | 63 |
| Rated short-circuit making current(peak) | kA | 63/50 | Restricted by fuse | 50 |
| Rated short-circuit breaking current | kA | - | Restricted by fuse | 20/20 |
| Rated transfer current | A | - | 17500/1400 | - |
| Rated load-break current | A | 630 | - | - |
| Rated closed-loop breaking current | A | 630 | - | 630 |
| Mechanical operation Loadbreak switch/circuit breaker Disconnector/Earthing switch | time | 5000 2000 | 5000 2000 | 10000 2000 |
| Resistance of the main circuit | μΩ | ≤120 | - | ≤120 |
| Pressure of compressed gas Rated pressure of compressed gas(absolute pressure) Min. pressure of compressed gas(absolute pressure) | bar | 1.3 1.2 | 1.3 1.2 | 1.3 1.2 |
| Annual relative leakage rate of SF6gas | % | ≤0.05 | ≤0.05 | ≤0.05 |
As a China ring main unit manufacturer, CEE provides a comprehensive range ofmedium voltage power distribution equipment, including bushing surge arrester,separable connector, overhead short circuit fault indicator, to name a few. Ourcompany has received the ISO9001 and ISO14001 certificates, and our productshave been CCC certified. We are located in Fuzhou City, Fujian Province, which providesus with easy access to convenient sea, land and air transportation.

- 630A, 24kV Two Side Bushing 630A, 24kV Two Side BushingThe CEE CQTG-24/630 two side bushing is designed for power cable sector and switchgear. It provides two DIN47636 standard

- 630A 12-24kV Integral Deadbreak Bushing with Flange 630A 12-24kV Integral Deadbreak Bushing with FlangeThe CEE YJSYCF-24/630 integral deadbreak bushing with flange combines the advantagesof reliable in

- 600A,35kV Integral Deadbreak Bushing 600A,35kV Integral DeadbreakBushingThe CEE YTGZD-35/600 integral deadbreak bushing combines the advantagesof reliable integral design with the operat

- Metal Stamping Parts Metal Stamping Parts The metal stamping parts are usually made of cold rolled steel sheet or hot rolled steel sheet. They a

- 200A, 15kV Fused Loadbreak Elbow Connector 200A, 15kV Fused Loadbreak Elbow ConnectorThefused loadbreak elbow connector combines theconventional 200A loadbreak elbow connector with


United Kingdom


English
Español
العرب