- Panel Meter
- Digital Multimeter
- PT-2 Three Phase Electromechanical Watt-Hour Meter
- PT-1 Three Phase Electromechanical Watt-Hour Meter
- PS-8 Single Phase Prepaid Electronic Meter - KWH Meter
- PS-7 Single Phase Multi-function Watt-Hour Meter
- PS-6 Single Phase Static Watt-Hour Meter
- PS-5 Single Phase Electromechanical Watt-Hour Meter
- PS-3 Single Phase Electromechanical Watt-Hour Meter
- PS-2 Single Phase Watt-Hour Meter
- Panel Meter
- Digital Multimeter
- PSA-5 Single Phase Electronic KWH Meter
- PSA-3 Single Phase Electronic KWH Meter
- PTA-2 Three Phase Electronic Multi-rate Watt-Hour Meter
- PSA-9 Single Phase Electronic Multi-rate Watt-Hour Meter
- PTA-1 Three Phase Electronic Watt-Hour Meter
- PSA-2 Single Phase DIN-rail Watt-Hour Meter
- PSA-1 Single Phase Electronic Watt-Hour Meter
- PT-6 Three Phase Electronic Prepaid Watt-Hour Meter
- PT-5 Three Phase Static Multi-function Energy Meter
- PT-3 Three Phase Static Active Watt-Hour Meter
- PT-2 Three Phase Electromechanical Watt-Hour Meter
- PT-1 Three Phase Electromechanical Watt-Hour Meter
- PS-8 Single Phase Prepaid Electronic Meter - KWH Meter
- PS-7 Single Phase Multi-function Watt-Hour Meter
- PS-6 Single Phase Static Watt-Hour Meter
- PS-5 Single Phase Electromechanical Watt-Hour Meter
- PS-3 Single Phase Electromechanical Watt-Hour Meter
- PS-2 Single Phase Watt-Hour Meter
- PS-1 Single Phase Watt-Hour Meter (Kilowatt Hour Meter)
- RA-2 Reactive Auto-compensation Power Controller
- RA-1 Reactive Auto-compensation Power Controller
- Low Voltage Power Capacitor
- TF Full Film Type H.V. Power Capacitor
- SH Self Healing Low Voltage Capacitor
- Power Capacitor / Power Controller
- Single Phase Watt-Hour Meter / KWH Meter (Kilowatt Hour Meter)
Digital Multimeter
Digital Multimeter
Digital Multimeter DM-1
3 3 /4 digits LCD with a Max. reading
of 3999.
Low battery indication
Overload protection
Safely 500V CAT Ⅱ
Accessories: Test lead, battery (AAA R03 Daum- 4
(1.5V)×2), instruction manual
Specifications
|
Function |
Measuring Range |
Accuracy |
|
DCV |
400m-500V |
±(0.8%+2) |
|
ACV |
4-500V |
±(1.2%+2) |
|
OHM |
400-40MΩ |
±(2.0%+2) |
|
FREQ |
99.99Hz~9.999MHz |
±(2.0%+3) |
|
Size/weight |
120×79×18mm/150g |
|
Digital Multimeter DM-2
3
1 / 2 digits LCD with a Max. reading of 1999.
Engineering unit annunciators.
Low battery indication.
Overload protection.
Audible continuity.
Accessories: Test lead, battery [6F22(9V)×1],
instruction manual
Specifications
|
c |
Measuring Range |
Accuracy |
|
DCV |
200m-2-20-200-1000V |
±0.5% |
|
ACV |
2-20-200-750V |
±1.2% |
|
DCA |
20μ-200μ |
±2.0% |
|
ACA |
-2m-20m-200m-2A-10A |
±2.0% |
|
OHM |
200μ-2m-20m-200m-2-10A |
±1.0% |
|
Diode |
200-2K-20K-200K-2M-2MΩ |
|
|
check |
2.8V/0.8mA |
|
|
hFE |
Vce 3V Ib 10μA |
|
|
Size/weight |
186×88×33mm/295g |
|
Digital Multimeter DM-3
3
1 / 2 digits LCD with a Max. reading of 1999.
Low battery indication.
Measuring capacitance.
Overload protection.
Audible continuity.
Accessories: Test lead, battery [6F22(9V)×1],
instruction manual.
Specifications of Digital Multimeter
|
Function |
Measuring Range |
Accuracy |
|
DCV |
200m-2-20-200-1000V |
±0.5% |
|
ACV |
200m-2-20-200-700V |
±1.2% |
|
DCA |
2m-20m-200m-10A |
±1.2% |
|
ACA |
20m-200m-10A |
±1.8% |
|
OHM |
200-2K-20K-200K-2M-20M-2MΩ |
±1.0% |
|
CAP |
2000p-20n-200n-2μ-20μF |
±2.5% |
|
Diode check |
3V/0.8mV |
|
|
hFE |
Vce 3V Ib 10μA |
|
|
Size/weight |
173×87×40mm/300g |
|
Digital Multimeter DM-5
Digits
LCD with a Max.
Reading of 4000.
Ranging method: Auto/manual.
Low battery indication.
Overload protection.
Audible continuity.
Red button.
Duty selecting button.
Auto power off.
Accessories: Test lead, battery [AAA(1.5V)×2],
instruction manual
Specifications
|
Function |
Measuring Range |
|
DCV |
400m-4-40-400-1000V |
|
ACV |
400m-4-40-400-750V |
|
DCA |
400μ-4m-40m-200m-10A |
|
ACA |
400μ-4m-40m-200m-10A |
|
OHM |
400-4K-40K-400K-4M-4MΩ |
|
CAP |
|
|
FREQ |
|
|
Diode check |
2.8V/1mV |
|
hFE |
Vce 3V Ib 10μA |
|
Size/weight |
189×91×31.5mm/487g(indluding holster) |
4
1 / 2 digits LCD with a Max. Reading of 19999.
Engineering unit annunciators
Data-hold function.
Low battery indication.
Capacitance measurement.
Frequency measurement.
Auto power off.
Accessories: Test lead, battery [6F22(9V)×1],
instruction manual
Specifications
|
Function |
Measuring Range |
Accuracy |
|
DCV |
200m-2-20-200-1000V |
|
|
ACV |
2-20-200-700V |
±0.1% |
|
DCA |
2m-20m-200m-20A |
±0.8% |
|
ACA |
20m-200m-20A |
±0.75% |
|
OHM |
|
|
|
CAP |
2n-20n-200n-2μ-2μF |
±1.2% |
|
FREQ |
10Hz-20KHz |
±0.5% |
|
Diode check |
3V/1mA |
±2.5% |
|
hFE |
Vce 3V, Ib 10μA |
±1.0% |
|
Size/weight |
170×88×38mm/318g |
|
Digital Multimeter DM-7
3
1 / 2 digits LCD with a Max. reading of 1999.
CAP Measurement from 0.1PF to 20mF.
Overload protection.
Accessories: Test lead, battery [6F22(9V)×1],
instruction manual
Specifications
|
Function CAP Size/weight |
Measuring Range |
Accuracy ±3.5% ±4.0% |
|
200p-20n-200n-2μ-20μ -200μ-2000μ-20mF |
||
|
180×82×38mm/300g |
Digital Multimeter DM-8
3
1 / 2 digits LCD with a Max. Reading of 19999.
The LCD can be freely adjusted to 70*Max.
Capacitance measurement.
Temperature measurement.
Auto power off.
Overload protection.
Accessories: Test lead, Temp, probe, battery [23A(12V)×1], instruction manual
Specifications
|
Function |
Measuring Range |
Accuracy |
|
DCV |
200m-2-20-200-600V |
±0.5% |
|
ACV |
200mV-2-20-200-600V |
±1.2% |
|
DCA |
2m-20m-200m-10A |
±1.2% |
|
ACA |
20m-200m-10A |
±1.2% |
|
OHM |
|
±0.8% |
|
CAP |
2n-20n-200n-2μ-20μF |
±2.5% |
|
Temperature |
-400℃~1000℃ |
±1.5% |
|
Diode Check |
2.8V/1mA |
|
|
hFE |
Vce 3V, Ib 10μA |
|
|
Size/weight |
186×86×33mm/275g |
|
|
Battery |
6F22(9V)×1 |
|

- Panel Meter Panel Meter Model: PM-96. PM-72. PM-48. PM-A96. PM-A72. PM-A48 Class: 1.5 Specs: 0.1A, 0.5A, 1A, 1.5A,3A, 5A, 7.5A,10A, 15A,

- Single Phase Watt-Hour Meter / KWH Meter (Kilowatt Hour Meter) Single Phase Watt-Hour Meter / KWH Meter (Kilowatt Hour Meter)

- Power Capacitor / Power Controller Power Capacitor / Power Controller

- SH Self Healing Low Voltage CapacitorSHSelf Healing Low Voltage CapacitorApplication Self healing low voltage capacitor is used in the system of 1200V and belowpower frequency AC electric

- TF Full Film Type H.V. Power CapacitorTF Full Film Type H.V. Power Capacitor Application Film type H.V. power capacitors are suitable for electric system with voltageabove 1KV to increase


United Kingdom


English
Español
Русский