- PC2 Fuel Oil Generator
- MAN B & W Fuel Oil Generator
- HFO Generator
- Soundproof Canopy
- Control Panel
- Alternator
- Mobile Power Station
- Francis Turbine Genset
- Pelton Turbine Genset
- Vertical Hydroelectric Generator
- Horizontal Hydroelectric Generator
- Tubular Turbine Genset
- Kaplan Turbine Genset
- Turgo Turbine Genset
- Hydraulic Generator
- Daihatsu Fuel Oil Generator
- Diesel Generator Sets
- THLC(CCEC) Cummins Genset
- THLC(DCEC) Cummins Genset
- THLM4000 MTU genset
- THLM2000 MTU genset
- THLM1600 MTU genset
- ABB Alternator
- Tellhow Alternator
- Yanmar Gensets
- VOLVO Gensets
- MTU Gensets
- LOVOL Gensets
- Cummins Gensets
- Perkins Gensets
Diesel Generator Sets
Standard configuration
| Engine(1500rpm/1800rpm) | Steel base frame |
| Alternator (50Hz/60Hz) | Starting lead-acid battery/battery connection cable |
| 40 Radiator | Output breaker |
| Industrial muffler | Intellectual control board |
| Water/fuel separator | Standard kits |
Optional configuration
| 50 Radiator | Auto fuel supplying system |
| Residential muffler | Maintenance free battery |
| Heavy anti-fire industrial muffler | Auto communication control system |
| Heavy air filter | Remote control system |
| Electric jacket heater | Auto parallel connection system |
| Combustion jacket heater | ATS board |
| External daily fuel tank | Specialized kits |
| Auto oil supplying system |
Powerful engine
Four-stroke industrial engine is built for reliability, with self-diagnostic features, high power output, high torque, easy maintenance, running period.
Enhanced safety
1.Safety first during the designing process.
2.A circuit breaker is provided to protect the generating set from short circuit or overloading.
3.Emergency shutting down button.
Advanced Alternator
All AMG synchronous alternators have brushless excitation controlled by state-of-the-art automatic voltage regulator. Alternator is self-excited, and does not require any external source of excitation power.
Automatic voltage regulator is used for AMG series; alternator is installed inside of terminal box.
Load from 0- 100%, frequency vibration within 0.5
No load wire volts max undulation ratio within 5%
Control Panel
1.Front panel configurable.
2.Automatic shutdown on fault condition.
3.Providing engine alarm and status information.
4.Multiple LCD languages (English, Chinese).
5.ATS and possibility of 16 generating sets\' parallel operation.
6.Graphical operating system.
Cooling and exhaust system
1.Exhaust silent system ensures smooth exhaust.
2.Cooling system ensures the generating set operate normally in 40 degrees centigrade ambient temperature.
3.Using of our optional accessories ensures generating set start and operate regularly even in low temperature area and desert.
High Reliability
Excellent Cooling System
Special cooling system is designed to decrease the temperature.
Anti-Vibration Mounting
Rubber diagonal isolators are specially designed to reduce vibration and prevent distortion and harmonics output of the generating set.
High Corrosion Resistance construction
The canopy is made of steel outer skin, and is lined with fire proof, acoustic material. Zinc plate or stainless steel fasteners and locks.
No load wire volts max undulation ratio within 5%
Automatic Start System
Starting and battery charging systems are either 12 or 24 volts, depending on engine model.
Wiring and space have been provided as standard equipment of standby applications.
Emergency Stop Button
Emergency stop button is located below the door for easy operation.
Designed with safety monitor & protection
PC control and protection
| Operation Display Item | Engine Stop | Load Interrupt | Malfunction Display |
| Low oil pressure | STD | STD | |
| High water temp. | STD | STD | |
| Over-current | STD | ||
| Electric leakage | STD | STD | |
| Insuf.Charging | STD | STD | |
| Low fuel consumption | STD | ||
| Plugging of air cleaner | STD | ||
| Over-speed | STD |
STD: Standard : Does not operate
Base Mounting Fuel Tank
The canopy is equipped with large capacity base mounting fuel tanks to prevent fuel spill inside of the canopy. The locking fuel cap is placed to avoid damage and simplify refueling.
Fuel inlet
Fuel level indicator
Fuel tube
Filler
Manual Fuel Pump
Strength of Certificate
Tellhow diesel generating sets are complied with IEC 60034. Rotating electrical machines. ISO8528-1-2-3-4-5-6-7-8-9. Reciprocating internal combustion engines drive alternating current generating sets.

- Daihatsu Fuel Oil Generator Daihatsu Fuel Oil GeneratorDaihatsu series engines are medium speed four-stroke engines produced in accordance with licensed technologies from Daihat

- Hydraulic Generator Hydraulic GeneratorBrief introductionTellhow Sci-Tech Co.,Ltd , based on a rich experience with production of hydraulic power equipments and auxiliar

- Turgo Turbine Genset Turgo Turbine GensetAccessory Tellhow SCI-Tech Co.,Ltd , based on a rich experience with production of machines and some isolated hydro power units,

- Kaplan Turbine Genset Kaplan Turbine GensetHydraulic turbines Tellhow SCI-Tech Co.,Ltd , based on a rich experience with production of machines and some isolated hydro pow

- Tubular Turbine Genset Tubular Turbine GensetProduct specification:Tubular Turbine GensetTurbine diameter0.6 m ~ 4 mWater headH= 4m ~ 15 mSuitable water flowQ= 0.8 m3/s ~ 6


United Kingdom


English
Français
Español
Русский
العرب
Português
中文