- Seismic Surveying
- Oil Free Piston 50-60HZ
- Atlas Copco Compressed Air Dryer
- Atlas Copco Air Dryer FD
- Atlas Copco Freeze Dryer FX 1-16
- Process Gas Compressor and Expander
- No Power Source Air Compressor
- Atlas Copco Pump WEDA Series
- Atlas Copco Industrial Power Tools
- Atlas Copco Construction Equipment
- Drilling Tool
- Open Air Rock Drilling Equipment
- Underground Rock Excavation Equipment
- Atlas Copco Mining Equipment
- Atlas Copco Filter 9 - 7200F
- Oil Free Rotary Tooth Air Compressor
- Oil Free Scroll Air Compressor SF1-15, SF17-22
- 500KW Oil Injected Screw Air Compressor
- 90KW Oil Injected Screw Air Compressor
- 30KW Oil Injected Screw Air Compressor GA11
- Atlas Copco Portable Lighting Machine
- Control Solutions
- Atlas Copco Explosion Proof Air Compressor
- Atlas Copco Booster Air Compressor
- Atlas Copco Portable Air Compressor
- Atlas Copco Oilless Screw Air Compressor
Atlas Copco Freeze Dryer FX 1-16
Atlas Copco Freeze Dryer FX 1-16
FX Freeze Dryer Wisdom Choice
Reliable performance
Stable pressure dew point
Condensing water vapor don\'t freeze
Water vapor will never enter the compressed air system
The Atlas Copco freeze dryer is simple, and has high reliability.
Big size high quality components
Design simple, already through the verification
Efficient control system (heat bypass)
Easy to install
Plug and play concept
Single-point circuit connection
All equipment attached to piping systems and power can be run directly
The Atlas Copco freeze dryer provides automatic adjustment.
Maintenance less workload
Maintenance interval time long
The Atlas Copco freeze dryer comes with fewer replacement components.
Man-machine engineering design, open main component faster
Large cost savings
Improve the life and reliability of tools and equipment
Reduce the pipeline leak, mean reduced energy expenditure
Reduce tools, machine and pipeline maintenance frequency
Reduce the inconvenience of faults and stop
Will carry water caused by the product defect is reduced to the minimum
No filtering, installation is complete
Pre filter
Pre filter can not only protect the dryer, but also remove the water, 1 micron big particle and 0.1 mg/m big oil
End filter:
End filter can remove 0.01 micron big particle and 0.01 mg/m big oil
Air system:
Finally it can offer clean and dry air, for air system and air instrument
Technical Parameters of 50HzModel
model | Outlet pressure dew point | Max working pressure | power | Compressed air connector | |||
| + 5 C / 41 F | + 3 C / 37 F |
| - |
| ||
| Inlet Flow Rate | Pressure Drop | Inlet Flow Rate | Pressure Drop |
| - |
|
| m/min | bar | m/min | bar | - |
| |
FX 1 | 0.42 | 0.20 | 0.36 | 0.15 | 16 | 230/1/50 Hz | 3/4" M |
FX 2 | 0.72 | 0.33 | 0.60 | 0.25 | 16 | 230/1/50 Hz | 3/4" M |
FX 3 | 0.96 | 0.33 | 0.84 | 0.25 | 16 | 230/1/50 Hz | 3/4" M |
FX 4 | 1.38 | 0.33 | 1.20 | 0.25 | 16 | 230/1/50 Hz | 3/4" M |
FX 5 | 2.10 | 0.40 | 1.80 | 0.30 | 16 | 230/1/50 Hz | 3/4" M |
FX 6 | 2.70 | 0.42 | 2.34 | 0.32 | 13 | 230/1/50 Hz | 1" F |
FX 7 | 3.48 | 0.50 | 3.0 | 0.38 | 13 | 230/1/50 Hz | 1" F |
FX 8 | 4.15 | 0.24 | 3.60 | 0.18 | 13 | 230/1/50 Hz | 1 1/2" F |
FX 9 | 4.75 | 0.33 | 4.09 | 0.25 | 13 | 230/1/50 Hz | 1 1/2" F |
FX 10 | 6.01 | 0.24 | 5.23 | 0.18 | 13 | 230/1/50 Hz | 1 1/2" F |
FX 11 | 7.51 | 0.26 | 6.49 | 0.20 | 13 | 230/1/50 Hz | 1 1/2" F |
FX 12 | 8.89 | 0.36 | 7.69 | 0.27 | 13 | 230/1/50 Hz | 1 1/2" F |
FX 13 | 11.53 | 0.33 | 10.03 | 0.25 | 13 | 400/3/50 Hz | 2" F |
FX 14 | 13.82 | 0.40 | 12.02 | 0.30 | 13 | 400/3/50 Hz | 2" F |
FX 15 | 17.30 | 0.40 | 15.02 | 0.30 | 13 | 400/3/50 Hz | 2" F |
FX 16 | 20.73 | 0.40 | 18.02 | 0.30 | 13 | 400/3/50 Hz | 2" F |
Reference Working Conditions:
Environment temperature: 25c
Inlet temperature: 35c
Working pressure: 7bar(g)
Notice:
Refrigerant: R134ais used inFX1-5
R404ais used inFX6-16
Restrictions:
top environment temperature: 43 C; minimum 5 C temperature environment: the highest temperature: 55, export C
Filter Choice
model | Outlet pressure dew point | |||||
| + 5 C / 41 F | + 3 C / 37 F | ||||
| Inlet flow | Pre filter | After filter | Inlet flow | Pre filter | After filter |
| l/s | - | l/s | - | ||
FX 1 | 7 | DD9 | PD9 | 6 | DD9 | PD9 |
FX 2 | 12 | DD17 | PD17 | 10 | DD17 | PD17 |
FX 3 | 16 | DD17 | PD17 | 14 | DD17 | PD17 |
FX 4 | 23 | DD32 | PD32 | 20 | DD32 | PD32 |
FX 5 | 35 | DD44 | PD44 | 30 | DD32 | PD32 |
FX 6 | 45 | DD44 | PD44 | 39 | DD44 | PD44 |
FX 7 | 58 | DD60 | PD60 | 50 | DD60 | PD60 |
FX 8 | 69 | DD120 | PD120 | 60 | DD60 | PD60 |
FX 9 | 79 | DD120 | PD120 | 68 | DD120 | PD120 |
FX 10 | 100 | DD120 | PD120 | 87 | DD120 | PD120 |
FX 11 | 125 | DD120 | PD120 | 108 | DD120 | PD120 |
FX 12 | 148 | DD150 | PD150 | 128 | DD150 | PD150 |
FX 13 | 192 | DD280 | PD280 | 167 | DD175 | PD175 |
FX 14 | 230 | DD280 | PD280 | 200 | DD280 | PD280 |
FX 15 | 288 | DD280 | PD280 | 250 | DD280 | PD280 |
FX 16 | 345 | DD280 | PD280 | 300 | DD280 | PD280 |
Flow Diagram
Refrigerants loop
1. gas-liquid separator: to ensure that only refrigerants gas can enter compressors, because refrigerant liquid will cause damage.
2. Refrigeration compressor: will gaseous refrigerants compressed into high-temperature high-pressure condition.
3. Maximum pressure switch (limited FX13-15)
4. Fan control only limit FX13 pressure switch (15)
5. Condenser fan
6. Condenser: will refrigerants, to make them slightly cooled by gas into liquid. Refrigerants in liquid form more effective.
7. Capillary filter: protect expansion equipment, make its from harmful particles damage.
8. Capillary: reduce pressure to reduce their refrigerant and improve the cooling ability temperature; Now all have become almost refrigerant liquid, only a few residual gas.
9. Heat bypass: adjust by gas - refrigerants heat exchangers refrigeration doses, ensure stable pressure dew point, eliminate condensate icy opportunities.
10. Air inlet: in hot saturated air into the dryer after, row breath - air heat exchangers air cooling of its own. Reduce the intake air temperature can reduce refrigerants loop load.
11. Gas - refrigerants heat exchanger: from compressed air heat transfer to cooling refrigerants, forcing the steam condensate of compressed air. Heat transfer and more efficient, the cold air, which will have more steam condensation.
12. Gas/gas heat exchanger
13. The water separator: from the airflow after cooling collect exhaling condensate. Isolation efficiency, the higher the pressure dew point will become better and better, and because not collect water vaporizing again, thereby reducing pressure dew point. Collect dropping through electronic sewage to the reliable methods from separator eduction.
14. Automatic drain
15. Air outlet: will exhaust air again, in order to avoid the heat in the factory line and condensation.

- Atlas Copco Air Dryer FD AtlasCopco Air Dryer FD"Adsorption type desiccant industry benchmark"Clean and dry compressed air: optimization busy production environment is ve

- Atlas Copco Compressed Air Dryer AtlasCopco Compressed Air DryerIt is very important to improve the workshop environment using clean and drycompressed air. Compressed air without

- Oil Free Piston 50-60HZOil Free Piston 50-60HZAtlas Copcocustomer designed and engineered oil free pistoncompressor & boosterZp oil free piston range 50hz-60hzAsolid exp

- Seismic SurveyingSeismic SurveyingSeismic Compressor--Reliable Power for Airguns in SeismicSurveyingGREENFIELD isyour specialist for high-pressure systems. As a pionee

- Atlas Copco Oilless Screw Air Compressor Atlas Copco Oilless Screw Air Compressor Atlas Copco Oilless Screw Air CompressorOil Free Rotary Screw Compressor ZR/ZT 55-750-FF and ZR/ZT 75-9


United Kingdom


English
中文