- Inverter
- Gallery
- Principle,Wiring
- Technical Parameters
- Gallery
- Physical Features
- Physical Features
- Technical Parameters
- Principle,Wiring
- Applications
- CATV UPS, EX-0614
- DC Axial UPS Cooling Fan
- UPS Cooling Fan
- 10-20kVA UPS
- 20kVA UPS and UPS higher than 20kVA
- 6-10kVA UPS
- 1-3kVA UPS
- 500VA-1200VA UPS
- HW9110E High Performance Integrated Outdoor Online UPS, 1kVA-10kVA
- GM Series 6 - 20kVA
- G Series 1 - 3kVA
- GM Series 6 - 20kVA
- G Series 1 - 3kVA
- LG Series 500-1200VA
- ST Series 1 - 3kVA
- HP9330C Series 10 - 80kVA
- GP Series 10 - 200kVA
- GP Series 6 - 30kVA
- HP9116C & HP9316C Series 6-20kVA UPS
- HP9116C Series 1 - 3kVA
- B Series 500-1200VA
- ST Series 1 - 3kVA
- HP9117C series1 - 3kVA
- GP series 10-200kVA UPS
- GP series 6-30kVA UPS
- HP9330C Series 10 - 80kVA
- HP9116CR & HP9316CR series 1-10kVA UPS
- HP9116C & HP9316C Series 6-20kVA UPS
- HP9116C Series 1 - 3kVA
- G / GM Series 6 - 20kVA
- G / GM Series 1 - 3kVA
- ST Series 1 - 3kVA
- GP series 10-200kVA UPS
- GP series 6-30kVA UPS
- HP9330C series 20-80kVA UPS
- HP9116CR & HP9316CR series 1-10kVA UPS
- HP9116C & HP9316C series 6-20kVA UPS
- HP9116C Series 1-3kVA UPS
- G-GM series 6-20kVA UPS
- G-GM Series 1-3kVA UPS
- Difference Between EPS and UPS
- Passive Power Filter
- Active Power Filter (APF)
- Power Filter
- UPS Cooling Fan
- UPS Battery Charger
- UPS SNMP Card
- Inverter UPS Accessories
- Lighting Power EPS (Emergency Power Supply)
- Lighting EPS (Emergency Power Supply)
- EPS (Emergency Power Supply)
- UPS System
- LED UPS
- LCD UPS
- Low Frequency Online UPS
- High Frequency Online UPS
- ST Series 1-3kVA UPS
- HP9117C Series 1-3kVA UPS
- Online UPS
- UPS (Uninterruptible Power Supply)
- Off Line UPS
Active Power Filter (APF)
Our active power filter is an advanced power electronic device. It is designed with a digital signal processor, and employs high frequency power electronic conversion technology.
Applications of Active Power Filter
The active power filter is particularly designed for harmonic suppression and dynamic reactive power compensation. It is widely used in power supply system of power systems, oil plants, tobacco plants, chemical factories, metallurgical factories pharmaceutical plants, shipbuilding factories, automobile factories, telecommunication companies, cement plants, mine factories, electrified railways, paper plants, precision machinery factories, welding plants, textile mills, print factories, precision electronics and semiconductor factories, etc.
Features of Active Power Filter
1. Real-time monitoring and dynamic compensation
Our active power filter adopts harmonic current detection technology to monitor the harmonic current at real time. Once instantaneous reactive power is detected, our active filter will offer dynamic compensation to the harmonic current immediately.
2. Excellent compensation performance
Our active power filter can eliminate the resonance produced by the harmonic of the power system, with the help of the system\'s impendance. Its compensation performance will not be affected by the impendance.
3. Flexible compensation
The active power filter is multifunctional. It not only can control the harmonic, but also can make reactive power compensation. Meanwhile, it also can improve the power factor.
Our active power filter can compensate either single harmonic or several harmonic. It also can control the indicated secondary harmonic while controlling the harmonic.
4. DSP intelligent monitoring
Our active power filter is designed with digital signal processor (DPS), so it has a accurate and useful harmonic monitoring and compensation. Furthermore, it has functions of intelligent monitoring and remote monitoring through which users can know the working status and running parameter of the active power filter at real-time.
5. Advanced power conversion design
The active power filter adopts the latest IGBT high-frequency switching devices and full-bridge PWM converters. It features high efficiency, stable performance, reliability, and small volume. Besides, the capacity of our active power filter can be designed according to your requirements.
6. Standard modular design
The power circuit or control circuit uses module or pluggable unit to carry out standardization of production. This greatly guarantees the reliability of our active power filter.
In addition, our active power filter is easy to maintain.
The Parameters of Active Power Filter
| Control harmonic current value | 45A | 75A | 100A | 150A | 200A | |
| Power supply voltage | 380 (1 15%) V | |||||
| Power supply frequency | 50 (1 1%) Hz | |||||
| Power supply phase quantity | Three phases three wires or three phases four wires | |||||
| Current transformer | / 5A | |||||
| Times of harmonic compensation | 2 ~ 25 times | |||||
| Response time | 20 ms | |||||
| Compensate ability | Complete compensation within the rated capacity. Once the required compensation capacity exceeds the rated capacity, users have to depend on the maximum compensate ability of APF. | |||||
| Protection | Over-current, over-temperature, power supply (under-voltage), power supply (short of phase), power supply (reverse phase). | |||||
| Cooling way | Forced air-cooled by fan | |||||
| Power loss | < 5% | |||||
| Display | LCD | |||||
| Working ambient temperature | -10 ~ + 45 | |||||
| Relative humidity | <90% ( 25) | |||||
| Noise | <65dB | |||||
| Protection class of enclosure | IP20 | |||||
| Body size (WHD)(mm) | 6001200400 | 6002200200 | 8002200600 | |||
| It\'s available to change if necessary. | ||||||
| Net weight | 150 kg | 200 kg | 400 kg | |||
SH Power Co.,Ltd. is a main manufacturer of active power filters. Over ten years manufacturing experience in this industry has enable us to offer high quality UPS products to our customers. These products could be off line UPS, online UPS, LCD UPS, LED UPS, and more.
Due to reliable performance and reasonable prices, our CE certified UPS products are widely exported to the United States, Russia, Brazil, Germany, etc.
For further inquiries and purchase of active power filters or any of our UPS products, please do contact us. We are competent that we are your one stop shopping centre for all your UPS needs.

- Passive Power Filter Passive Power FilterOur SPF series passive power filter is designed for different loading solutions. It can filter harmonic and provide capacitive re

- Difference Between EPS and UPS Difference Between EPS and UPSItemEPS(three phases emergency power supply)UPS (uninterruptible power supply)Electricity savingIt operates in sleep mo

- G-GM Series 1-3kVA UPS G-GM Series 1-3kVA UPSApplication of G-GM Series 1-3kVA UPSG-GM series 1-3kVA can be applicable to servers, data centers, critical network devices, s

- G-GM series 6-20kVA UPS G-GM series 6-20kVA UPSApplications of G-GM series 6-20kVA UPSG - GM series 6-20kVA is widely applied to servers, data centers, critical network devi

- HP9116C Series 1-3kVA UPS HP9116C Series 1-3kVA UPSApplications of HP9116C Series 1-3kVA UPSHP9116C Series 1-3kVA can be widely suitable for servers, data centers, critical ne


United Kingdom


English
Español
Русский