Table 1. Zinc Coating

Specified Diameter of Coated Wre

Class A

Class B

Class C

1.6-1.9

210

420

630

>1.9-2.3

220

440

660

>2.3-2.7

230

460

690

>2.7-3.1

240

480

720

>3.1-3.5

260

520

780

>3.5-3.9

270

540

810

>3.9-4.5

275

550

825

>4.5-4.8

300

600

900

Table 2. Tensile Requirements

Specified Diameter

Stress at 1 % Extension min Mpa

Ultimate Tensile Strength min MPA

Elongation in 250mm, min, 1%

Class A

Class B

Class C

Class A

Class B

Class C

Class A

Class B

Class C

1.6-2.3

1310

1240

1170

1450

1380

1310

3

3

3

>2.3-3.05

1280

1210

1140

1410

1340

1280

3.5

3

3

>3.05-3.6

1240

1170

1100

1410

1340

1280

4

3

3

>3.6-4.8

1170

1100

1070

1380

1280

1240

4

4

4

Table 3. Initial Settings for Determining Stress 1% Extension

Specified Diameter, mm

Initial Stress, MPA

Initial Setting of Extensometer, mm/mm

1.6-2.3

100

0.0005(0.05% extension)

>2.3-3.05

190

0.0010(0.10% extension)

>3.05-4.8

290

0.0015(0.15% extension)

Table 4. Mandrel Size for Adherence Test

Specified Wire Diameter,mm

Ratio of Mandrel Diameter to Wire Diameter

1.6-2.3

3

>2.3-3.05

4

>3.05-4.8

5

Table 5. Permissible Variations in Diameter of Zinc-Coated Steel Wire

Specified Diameter, mm

Permissible Variation, mm

Plus

Minus

1.6-2.3

0.04

0.03

>2.3-3.05

0.05

0.05

>3.05-3.6

0.08

0.05

>3.6-4.8

0.1

0.08

Feedback Form
Other Products
  • ASTM B498 ASTM B498 Standard Dia of Wire, mm Tensile Strength, Mpa Stress at 1% Extension, Mpa Coating, g/m2 CLASS A CLASS B
  • EN 50189 EN 50189 Standard Table 1. Initial Settings for Determining Stress 1% Extension Nominal Wire Diameter, mm Initial Stress, N/
  • ASTM A475 ASTM A475 Standard Dia. of strand, in(mm) Minimum Breaking Strength of Strand,1bf(kN) Weight of Zine Coating, g/m2 High Strength
  • BS4565-1990 BS4565-1990 Standard Table 1. Initial Settings for Determining Stress 1% Extension Nominal Diameter of Galvanized Steel Wire Initi

United States | Argentina | Brazil | China | France | Germany | Japan | Korea | Russia | Spain | Switzerland | Thailand | UAE | United Kingdom | Vietnam | Poland | Italy | Morocco | Malaysia | Portugal | India | Canada