UserName: PassWord:
My account
My account
AL61 Molded Case Circuit Breaker (MCCB) ,China AL61 Molded Case Circuit Breaker (MCCB)
Product List
ETW International,ETW Manufacturers
A
AL61 Molded Case Circuit Breaker (MCCB)

AL61 Molded Case Circuit Breaker (MCCB)


AL61 Molded Case Circuit Breaker (MCCB)

1. Specifications of Molded Case Circuit Breaker:
Manufacture stardand:IEC60947-2
Fixing type thermal trip
Fixing type magnetic trip
2. MAX. Rated short-circuit breaking capacity:

Hull

220/240Vac

380/415Vac

660/690Vac

250Vdc*

126H

65kA

25kA

10kA

226H

35kA

25kA

226N

40kA

40kA

12kA

10kA

226E

100km

70kA

14kA

20kA

3. Parameters of Molded Case Circuit Breaker:

Description

Rated current(A)

Description

Rated current(A)

126H-25kA

226N-40kA

MCCB

16

MCCB

63

MCCB

20

MCCB

80

MCCB

25

MCCB

100

MCCB

32

MCCB

125

MCCB

40

MCCB

160

MCCB

50

MCCB

200

MCCB

63

MCCB

225

MCCB

80

MCCB

100

226H-25kA

226E-70kA

MCCB

63

MCCB

63

MCCB

80

MCCB

80

MCCB

100

MCCB

100

MCCB

125

MCCB

125

MCCB

160

MCCB

160

MCCB

200

MCCB

200

MCCB

225

MCCB

225

4. Accessories & Auxiliary Equipment ofMolded CaseCircuit Breaker:

Handles

Locks

AA

Auxiliary switch

2NO+2NC

UV

Owe-voltage trip

415V

SR

Cent trip

240V

UV2

Owe-voltage trip

240V

As a manufacturer of high qualityelectronic components, our miniature circuit breaker, earth leakage circuitbreaker, AC contactor, Power relay, etc. can meet your needs.

Feedback Form
Other Products
  • AL60 Surge Protective Device (SPD)AL60 SurgeProtection Device (SPD)1.Power Distribution SystemAL60 Surge Protection Device can be used in the entrance of the low tensionpower supply ne
  • Interlocking Contactor Interlocking Contactor1. Specifications of InterlockingContactor: Type Rated current AC-3(A) Controlled power(KW) 220V 380V
  • AA07 AC Contactor AA07 AC ContactorSpecifications of AA07 AC Contactor: For motor control, from 6 to 630A(AC-3) for the control of distribution circuits, from 16 t
  • AA08 AC Contactor AA08 AC Contactor1. Technical Specifications of AA08 AC Contactor: Type Rated Thermal current (A) , Rated operation current(A) Co
  • DC Operated AC Contactor DC Operated AC Contactor1. Specifications of DC Operated ACContactor: Type Rated working current A leA (AC-3) Rated heat current Ith(A)

United States | Argentina | Brazil | China | France | Germany | Japan | Korea | Russia | Spain | Switzerland | Thailand | UAE | United Kingdom | Vietnam | Poland | Italy | Morocco | Malaysia | Portugal | India | Canada

Copyright © 2008 - ETW International. All rights reserved.