UserName: PassWord:
My account
My account
AL33 Residual Circuit Device (RCD),China AL33 Residual Circuit Device (RCD)
Product List
ETW International,ETW Manufacturers
A
AL33 Residual Circuit Device (RCD)

AL33 Residual Circuit Device (RCD)


AL33 Residual Current Device (RCD)

AL33 Residual Current Device Introduction:

The Residual Current Device (RCD) is in conformity with thestandards of IEC1008, GB16916 and BS EN61008. The RCD can cut off the faultcircuit immediately on the occasion of shock hazard or earth leak of trunk,thus it is suitable to avoid the shock hazard and fire caused by earth leak.
The Residual Current Device (RCD) is mainly suitable for using in variety ofplants and enterprises, building construction, commerce, guesthouses andfamilies. It can be used in circuits up to single phase 230V, three phases400V50 to 60Hz,RCD is not suitable for using on DC pulsesystem.
Standard: led 1008,GB 16916,BS En61008
Rated voltage(Un): 2 poles: 230V AC4 poles: 400V AC
Rated current (In):25,40,63A
Rated residual operating current(In):30,100,300,500mA
Rated residual non-operating current (I~n):0.5 In
Residual current off-time: ~< 0.1 s
Minimum value of rated making and breaking capacity (Im):lKA
Rated conditional short-circuit current(Inc):In=25,40A Inc=1500A In=63AInc=3000A
Endurance: on load:200cycles
Off load:2000cycles


ElectricalSpecifications of AL33 Residual Current Device:

Design according to

ICE 1008 (EN 61008)

Tripping time

undelayed min. 10 ms delay min.40 ms delay with selective disconnecting function

Rated voltage

230/400V;50Hz

Rated tripping current

10,30,100,300,500mA

Sensitivity

AC and pulsating DC

Rated short

10KA with 63A gL back-up fuse

Circuit strength

10KA with 80A gL(F7-80 and-863)

6KA(rated current 63A) with 63A gL

Maximum back-up fuse for

63A gL

Short circuit protection

80A gL (F7-80 and-863)

Maximum back-up fuse for

45A gL(F7-25 and-40A)

Oveload protection

40AgL(F7-80A)

Resistance to climatic conditions

according to IED 1008

Degree of protection

built-in switch IP 40

Endurance electrical comp. mech comp.

~<4.000 operating cycles ~>20.000 operating cycles

Frame size

45mm

Socket size

80mm

Device width

35mm (2mod.), 70mm (4mod.)

Mounting

quick fastening with 2 lock-in

Positions on DIN rail En50022

Upper and lower terminals

open mouthed/lift terminals

Terminal protection

finger and hand touch safe,

VBG 5, OVE-EN 6

Terminal capacity

1---25m2

Busbar thickness

0.8 - 2mm

High quality electronic components such asminiature circuit breaker, earth leakage circuit breaker, AC contactor, Powerrelay, etc. can be found in our company.

Feedback Form
Other Products
  • AL18 Miniature Circuit BreakerAL18 Miniature Circuit BreakerMiniature Circuit Breaker Application:AL18 series miniature circuit breaker is used in lighting distribution systemor mo
  • Industrial Socket & PlugIndustrial Socket & Plug Nominal current (A): 16A/32A Nominal voltage (V)110-130V No. poles: 2P+E Protection degree: IP67
  • Push buttonPush buttonAlbet sold all its electronic componentsin international market, and has gain good reputation for the high quality ofthese electronic compo
  • IndicatorsIndicatorsAlbet sold all itselectronic components in international market, and has gain good reputation forthe high quality of these electronic compon

United States | Argentina | Brazil | China | France | Germany | Japan | Korea | Russia | Spain | Switzerland | Thailand | UAE | United Kingdom | Vietnam | Poland | Italy | Morocco | Malaysia | Portugal | India | Canada

Copyright © 2008 - ETW International. All rights reserved.