- WYA-Z/WYA-ZT Automatic ABBE Digital Refractometer
- 723N Visible Spectrophotometer
- G Series Spectrophotometer
- WYA ABBE Refractometer
- FP6410 Flame Photometer
- FP640 Flame Photometer
- GC122 Gas Chromatograph
- GC112A Gas Chromatograph
- GC102AF/GC102AT Gas Chromatograph
- 4530 Atomic Absorption Spectrophotometer
- AA320N Atomic Absorption Spectrophotometer
- F96PRO Fluorescence Spectrophotometer
- F93 Fluorescence Spectrophotometer
- S410 NIR Spectrophotometer
- 765 UV-VIS Spectrophotometer
- 757 UV-VIS Spectrophotometer
- WGT-S Hazemeter
- X-4 Melting Point Apparatus With Microscope
- WRS-2/2A Micro Processor Melting Point Apparatus
- WRS-1B Digital Melting Point Apparatus
- WRR Visual Melting Point Apparatus
- SGW-1/SGW-2/SGW-3 Automatic Polarimeter
- WZZ-2S Automatic Polarimeter
- WZZ-3 Automatic Polarimeter
- WZZ-2B Automatic Polarimeter
- WXG-4 Disc Polarimeter
- WYA-2S ABBE Digital Refractometer
- WYA-2W ABBE Refractometer
- Temperature Sensor
- Dissolved Oxygen Sensor
- Ion Selective Sensors
- Metal Sensor
- Conductivity Sensor
- Reference Sensor
- pH Sensor
- COD-571/572 Chemical Oxygen Demand Meter
- ZDJ-5 Automatic Titrator
- ZDJ-4A Automatic Potential Titrator
- ZD-2 Automatic Potential Titrator
- DZS-708 Multi-Parameter Water Quality Meter
- DZS-706 Multi-Parameter Water Quality Meter
- DZB-718, DZB-712 Portable Multi-Parameter Meter
- PXB-286 Portable Ion Meter
- PXSJ-216 Ion Meter
- PXSJ-226 Ion Meter
- JPSJ-605 Benchtop Dissolved Oxygen Meter
- JPB-607A Portable Dissolved Oxygen Meter
- JPBJ-608 Portable Dissolved Oxygen Meter
- DDSJ-318 Conductivity Meter
- DDS-307A Conductivity Meter
- DDSJ-308A Conductivity Meter
- DDB-303A Portable Conductivity Meter
- DDBJ-350 Portable Conductivity Meter
- PHSJ-5 pH Meter
- PHSJ-3F pH Meter
- PHSJ-4A pH Meter
- PHS-3G Benchtop pH Meter
- PHS-3E pH Meter
- PHS-3C pH Meter
- PHB-4 Portable pH Meter
- PHBJ-260 Portable pH Meter
- WGZ-2000 Ratio Turbidimeter
- WGZ-200 Ratio Turbidimeter
- WSB-L White Meter
- WSF-J Spectroscopic Color Photometer
- WSC-S Colorimeter and Color Difference Meter
- WSL-2 Tintometer
- WGW Photoelectric Hazemeter
- WQS Vibrator
AA320N Atomic Absorption Spectrophotometer
AA320NAtomic Absorption Spectrophotometer
Features
1.Built-inComputer Data Processing and LCD display
It is reliable with the functions of integral holding, peak height and area, autozero adjusting, deuterium lamp and background, multi-linear and nonlinearcurves fitting, various parameters and working curves displayed in screen andreport printing, etc. The atomic absorption spectrophotometer is equipped withinterface for externally linking PC.
2.Goodbasic line stability
The double-beam system ofoptimized design can automatically compensate the light source drift andwavelength drift caused by the variation of temperature (with the function ofeliminating the affection of wavelength drift on the base line stability) andelectronic circuit drift. The cathode lamp does not need to be pre-heated for along time and the sample can be analyzed immediately. The atomic absorptionspectrophotometer is the preferable instrument chosen by users to conduct afast analysis of samples.
3.OpticalPath of High Energy
A total reflection system is used to eliminate color difference in full range.By means of chemical conversion, a round light spot of the light source becomesa long light spot which enters into the slit, enhancing the light flux ofdouble beam.
4.Long-lifeand Anti-corrosive Atomization System
The burner of the atomic absorption spectrophotometer is made of new typetitanium alloys, anti-corrosive and fast thermal equilibrium. It meets therequirement of measurement sensitivity without water-cooling.
5.Multi-functionalAnalysis Mode
The atomic absorption spectrophotometer can supportmethods of flame absorption, flame emission, graphite furnace atomic absorptionand hydride generation.
6.Safeand Reliable Gas Path System
Special devices of quick gas conversion and safety protection can be used toanalyze air-acetylene flame and extend the analytic elements to reach more than60.
Technical Specifications
| Working spectral range | 190-900nm |
| Wavelength accuracy | 0.5nm |
| Wavelength repeatability | 0.3nm (single direction) |
| Spectrum bandwidth | 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm |
| Resolution | <40% |
| Base line stability | 0.004Abs/30min |
| Characteristic concentration of copper | 0.04mg/ml/1% |
| Detection limit of copper | 0.008mg/ml |
| Background calibration ability | Greater than 30 times |
| Interface | RS 232 |
Standard Configuration
Several decades of accessories including aircompressor, one piece of HCL, gas external pipe, water knockout gas filter andothers.
Optional Accessories
1. GA3202HGA graphite furnace system
Used to conduct trace and ultra-trace analysis with an absolute sensitivity of 10-10-10-12gram.
2. Hydride generator(Totally automatic)
Making the characteristic concentration of As, Se, Sb, Bi, Pb, Sn, Te, Ge, In,Tl, Cd and Zn lower than ppb level with cold atomic mercury measurement method.
3. Hollow cathodelamp
All specifications are available.
4. Graphite tube
All specifications are available.
5. Software with I/Oport
ShippingPackage
Main instrument: 1260x800x730mm 160Kg
Accessories: 880x600x1010mm65Kg
As a professional atomic absorption spectrophotometer manufacturer and supplierin China, INESA alsoprovides fluorescence spectrophotometer, automatic potential titrator, chromatograph, pH meter, and flame photometer,etc.

- 4530 Atomic Absorption Spectrophotometer 4530 Atomic Absorption SpectrophotometerFeatures1. Using PC control, the atomic absorptionspectrophotometer can flexibly select the flame and graphit

- GC102AF/GC102AT Gas Chromatograph GC102AF/GC102ATGas ChromatographFeatures1. Allcontrol and application parameters of this gas chromatograph can be set upthrough the keyboard. Functio

- GC112A Gas Chromatograph GC112A Gas ChromatographFeatures1. The gas chromatograph offers high accuracy oftemperature control (optimum: 0.05C), high reliability andanti-inter

- GC122 Gas Chromatograph GC122Gas ChromatographFeatures1. The GC122 gas chromatograph is newlydesigned, high performance HRGC.2. The double FID detectors in the basic typefea

- FP640 Flame Photometer FP640Flame PhotometerFeatures1. This flame photometer is equipped with an LCD displayand LPG gas path system, so it is easy to operate and has stable


United Kingdom


English
Español
Português